<?xml version="1.0"?><Regulation lims:pit-date="2025-08-28" hasPreviousVersion="true" lims:lastAmendedDate="2025-08-28" lims:current-date="2025-09-01" lims:inforce-start-date="2017-06-02" lims:fid="745335" lims:id="745335" gazette-part="II" regulation-type="SOR" xml:lang="en" in-force="yes" xmlns:lims="http://justice.gc.ca/lims"><Identification lims:inforce-start-date="2017-06-02" lims:fid="745336" lims:id="745336"><InstrumentNumber>SOR/2008-197</InstrumentNumber><RegistrationDate><Date><YYYY>2008</YYYY><MM>6</MM><DD>12</DD></Date></RegistrationDate><ConsolidationDate lims:inforce-start-date="2017-06-02"><Date><YYYY>2025</YYYY><MM>9</MM><DD>2</DD></Date></ConsolidationDate><EnablingAuthority lims:inforce-start-date="2017-06-02" lims:fid="745338" lims:id="745338"><XRefExternal reference-type="act" link="C-15.31">CANADIAN ENVIRONMENTAL PROTECTION ACT, 1999</XRefExternal></EnablingAuthority><LongTitle lims:inforce-start-date="2017-06-02" lims:fid="745339" lims:id="745339">Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations</LongTitle><RegulationMakerOrder><RegulationMaker>P.C.</RegulationMaker><OrderNumber>2008-1048</OrderNumber><Date><YYYY>2008</YYYY><MM>6</MM><DD>12</DD></Date></RegulationMakerOrder></Identification><Order lims:inforce-start-date="2017-06-02" lims:fid="745340" lims:id="745340"><Provision lims:inforce-start-date="2017-06-02" lims:fid="745341" lims:id="745341" format-ref="indent-0-0" language-align="yes" list-item="no"><Text>Whereas, pursuant to subsection 332(1)<FootnoteRef idref="footnotea_e">a</FootnoteRef> of the <XRefExternal reference-type="act" link="C-15.31">Canadian Environmental Protection Act, 1999</XRefExternal><FootnoteRef idref="footnoteb_e">b</FootnoteRef>, the Minister of the Environment published in the <XRefExternal reference-type="other" link="gazette">Canada Gazette</XRefExternal>, Part I, on April 7, 2007 a copy of the proposed <XRefExternal reference-type="regulation" link="SOR-2008-197">Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations</XRefExternal>, substantially in the annexed form, and persons were given an opportunity to file comments with respect to the proposed Regulations or to file a notice of objection requesting that a board of review be established and stating the reasons for the objection;</Text><Footnote id="footnotea_e" placement="page"><Label>a</Label><Text>S.C. 2004, c. 15, s. 31</Text></Footnote><Footnote id="footnoteb_e" placement="page"><Label>b</Label><Text>S.C. 1999, c. 33</Text></Footnote></Provision><Provision lims:inforce-start-date="2017-06-02" lims:fid="745342" lims:id="745342" format-ref="indent-0-0" language-align="yes" list-item="no"><Text>Therefore, Her Excellency the Governor General in Council, on the recommendation of the Minister of the Environment, pursuant to section 209 of the <XRefExternal reference-type="act" link="C-15.31">Canadian Environmental Protection Act, 1999</XRefExternal><FootnoteRef idref="footnoteb_e">b</FootnoteRef>, hereby makes the annexed <XRefExternal reference-type="regulation" link="SOR-2008-197">Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations</XRefExternal>.</Text></Provision></Order><Body lims:inforce-start-date="2017-06-02" lims:fid="745343" lims:id="745343"><Heading lims:inforce-start-date="2017-06-02" lims:fid="745344" lims:id="745344" level="1"><TitleText>Interpretation</TitleText><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745346" lims:id="745346">SOR/2017-110, s. 19(F)</HistoricalNoteSubItem></HistoricalNote></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745347" lims:id="745347"><Label>1</Label><Text>The following definitions apply in these Regulations.</Text><Definition lims:inforce-start-date="2017-06-02" lims:fid="745348" lims:id="745348" generate-in-text="no"><Text><DefinedTermEn>aboveground tank</DefinedTermEn> means a tank that operates at atmospheric pressure and that has all of its volume either above ground or encased within an unfilled secondary containment. (<DefinedTermFr>réservoir hors sol</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745349" lims:id="745349" generate-in-text="no"><Text><DefinedTermEn>allied petroleum product</DefinedTermEn> means a product set out in Schedule 1. (<DefinedTermFr>produit apparenté</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745350" lims:id="745350" generate-in-text="no"><Text><DefinedTermEn>CCME Code of Practice</DefinedTermEn> means the <XRefExternal reference-type="other">Environmental Code of Practice for Aboveground and Underground Storage Tank Systems Containing Petroleum and Allied Petroleum Products</XRefExternal> published by the Canadian Council of Ministers of the Environment in 2003. (<DefinedTermFr>Code de recommandations techniques du CCME</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745351" lims:id="745351" generate-in-text="no"><Text><DefinedTermEn>certification mark</DefinedTermEn> means the mark, such as a tag, label, plate or embossing, on or affixed to a tank or a component of a storage tank system, certifying that the tank or component conforms to the standards of a certification organization accredited by the Standards Council of Canada or conforms to the standards of the American Petroleum Institute or of the ASTM International. (<DefinedTermFr>marque de certification</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745352" lims:id="745352" generate-in-text="no"><Text><DefinedTermEn>corrosion expert</DefinedTermEn> means a professional engineer experienced in corrosion protection or a person recognized by NACE International as a corrosion specialist. (<DefinedTermFr>expert en corrosion</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745353" lims:id="745353" generate-in-text="no"><Text><DefinedTermEn>free oil</DefinedTermEn> means the non-soluble, non-emulsified petroleum product or allied petroleum product layer that accumulates in an oil-water separator. (<DefinedTermFr>huile libre</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745354" lims:id="745354" generate-in-text="no"><Text><DefinedTermEn>Minister</DefinedTermEn><Repealed>[Repealed, SOR/2012-99, s. 20]</Repealed></Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745355" lims:id="745355" generate-in-text="no"><Text><DefinedTermEn>partially buried tank</DefinedTermEn> means a tank that has part of its volume above ground and part of its volume below ground, unless all of the tank volume is encased within an unfilled secondary containment. (<DefinedTermFr>réservoir partiellement enfoui</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745356" lims:id="745356" generate-in-text="no"><Text><DefinedTermEn>petroleum product</DefinedTermEn> means, other than an allied petroleum product, a single hydrocarbon or a mixture of at least 70% hydrocarbons by volume, refined from crude oil, with or without additives, that is used or could be used as a fuel, lubricant or power transmitter, and includes used oil, but does not include propane, paint and solvents. (<DefinedTermFr>produit pétrolier</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745357" lims:id="745357" generate-in-text="no"><Text><DefinedTermEn>piping</DefinedTermEn> means pipes and tubing, including fittings and valves, that are for the handling and storage of petroleum products and allied petroleum products. (<DefinedTermFr>raccordement</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745358" lims:id="745358" generate-in-text="no"><Text><DefinedTermEn>secondary containment</DefinedTermEn> means containment that prevents liquids that leak from a storage tank system from reaching outside the containment area and includes double-walled tanks, piping, liners and impermeable barriers. (<DefinedTermFr>confinement secondaire</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745359" lims:id="745359" generate-in-text="no"><Text><DefinedTermEn>separated solids</DefinedTermEn> means the particulate material that settles at the bottom of an oil-water separator. (<DefinedTermFr>solide séparé</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745360" lims:id="745360" generate-in-text="no"><Text><DefinedTermEn>spill</DefinedTermEn><Repealed>[Repealed, SOR/2017-110, s. 20]</Repealed></Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745361" lims:id="745361" generate-in-text="no"><Text><DefinedTermEn>storage tank system</DefinedTermEn> means a tank or commonly connected tanks and all piping, vents, pumps, sumps, diking, overfill protection devices, spill containment devices and oil-water separators. In the case of a system located at an airport, the system ends at the pump discharge. (<DefinedTermFr>système de stockage</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745362" lims:id="745362" generate-in-text="no"><Text><DefinedTermEn>tank</DefinedTermEn> means a closed container with a capacity of more than 230 L that is designed to be installed in a fixed location. (<DefinedTermFr>réservoir</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745363" lims:id="745363" generate-in-text="no"><Text><DefinedTermEn>transfer area</DefinedTermEn> means the area around the connection point between a delivery truck, railcar, aircraft or vessel and a storage tank system in which the tanks have an aggregate capacity of more than 2 500 L. (<DefinedTermFr>aire de transfert</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745364" lims:id="745364" generate-in-text="no"><Text><DefinedTermEn>underground tank</DefinedTermEn> means a tank that operates at atmospheric pressure and that has all of its storage volume below ground and completely surrounded by fill. (<DefinedTermFr>réservoir souterrain</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2017-06-02" lims:fid="745365" lims:id="745365" generate-in-text="no"><Text><DefinedTermEn>used oil</DefinedTermEn> means oil — other than oils derived from animal or vegetable fats, other than crude oil or recovered fuel oils spilled onto land or into water and other than wastes from petroleum refining operations — that has become unsuitable for its original purpose due to the presence of impurities or the loss of original properties, including</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745366" lims:id="745366"><Label>(a)</Label><Text>lubricating oil for use in engines, turbines, or gears;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745367" lims:id="745367"><Label>(b)</Label><Text>hydraulic fluid, including transmission fluid; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745368" lims:id="745368"><Label>(c)</Label><Text>insulating oil. (<DefinedTermFr>huile usée</DefinedTermFr>)</Text></Paragraph></Definition><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745370" lims:id="745370">SOR/2012-99, s. 20; SOR/2017-110, s. 20</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745371" lims:id="745371"><Label>1.1</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745372" lims:id="745372"><Label>(1)</Label><Text>A method or standard that is incorporated by reference into these Regulations is incorporated as amended from time to time.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745373" lims:id="745373"><Label>(2)</Label><Text>For the purposes of interpreting documents that are incorporated by reference into these Regulations, “should” must be read to mean “must” and any recommendation or suggestion must be read as an obligation.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745375" lims:id="745375">SOR/2017-110, s. 21</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745376" lims:id="745376" level="1"><TitleText>Application</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745377" lims:id="745377"><Label>2</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745378" lims:id="745378"><Label>(1)</Label><Text>These Regulations apply to any storage tank system located in Canada in which petroleum products or allied petroleum products are stored and</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745379" lims:id="745379"><Label>(a)</Label><Text>that is operated by a federal department, board or agency, or belongs to Her Majesty in right of Canada;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745380" lims:id="745380"><Label>(b)</Label><Text>that is operated to provide a service to, or belongs to, a federal work or undertaking that is</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745381" lims:id="745381"><Label>(i)</Label><Text>a port authority set out in the schedule to the <XRefExternal reference-type="act" link="C-6.7">Canada Marine Act</XRefExternal>,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745382" lims:id="745382"><Label>(ii)</Label><Text>an <DefinitionRef>airport</DefinitionRef> within the meaning of subsection 3(1) of the <XRefExternal reference-type="act" link="A-2">Aeronautics Act</XRefExternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745383" lims:id="745383"><Label>(iii)</Label><Text>a railway;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745384" lims:id="745384"><Label>(c)</Label><Text>that is located on federal land or aboriginal land; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745385" lims:id="745385"><Label>(d)</Label><Text>that is operated by a Crown corporation, as defined in subsection 83(1) of the <XRefExternal reference-type="act" link="F-11">Financial Administration Act</XRefExternal>, or that belongs to such a corporation.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745386" lims:id="745386"><Label>(2)</Label><Text>These Regulations do not apply to</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745387" lims:id="745387"><Label>(a)</Label><Text>storage tank systems located in a building that provides secondary containment equivalent to a maximum hydraulic conductivity of 1 x 10<Sup>-6</Sup> cm/s, on a continuous basis;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745388" lims:id="745388"><Label>(b)</Label><Text>storage tank systems containing unprocessed petroleum products resulting from or used during oil or natural gas exploration;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745389" lims:id="745389"><Label>(c)</Label><Text>storage tank systems that have aboveground tanks in which the aggregate capacity of the tanks is 2 500 L or less and the systems are connected to a heating appliance or emergency generator; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745390" lims:id="745390"><Label>(d)</Label><Text>storage tank systems regulated under the <XRefExternal reference-type="act" link="N-7">National Energy Board Act</XRefExternal> or the <XRefExternal reference-type="act" link="O-7">Canada Oil and Gas Operations Act</XRefExternal>.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745392" lims:id="745392">SOR/2017-110, s. 22</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745393" lims:id="745393" level="1"><TitleText>General Requirements</TitleText></Heading><Section lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:lastAmendedDate="2020-10-26" lims:fid="745394" lims:id="1273255"><Label>2.1</Label><Subsection lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273256" lims:id="1273256"><Label>(1)</Label><Text>A person must not release — or permit or cause any release of — a petroleum product or allied petroleum product, in liquid form in the environment, from a storage tank system.</Text></Subsection><Subsection lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273257" lims:id="1273257"><Label>(2)</Label><Text>Subsection (1) does not apply if the released product does not reach outside the secondary containment of the storage tank system.</Text></Subsection><Subsection lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273258" lims:id="1273258"><Label>(3)</Label><Text>A person must not release — or permit or cause any release of — a petroleum product or allied petroleum product, in liquid form in the environment, during the transfer of the product to or from a storage tank system.</Text></Subsection><Subsection lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273259" lims:id="1273259"><Label>(4)</Label><Text>Subsection (3) does not apply if the released product does not reach outside the transfer area of the storage tank system and if that transfer area is designed in accordance with subsection 15(1).</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745398" lims:id="745398">SOR/2017-110, s. 23</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273254" lims:id="1273254" lims:enactId="1272353">SOR/2020-235, s. 1</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745399" lims:id="745399"><Label>3</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745400" lims:id="745400"><Label>(1)</Label><Text>Subject to subsections (2) to (4), the owner or operator of a storage tank system that leaks a liquid must, without delay, temporarily withdraw from service, in accordance with section <XRefInternal>43</XRefInternal>, either</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745401" lims:id="745401"><Label>(a)</Label><Text>the leaking component, if it can be isolated from the system; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745402" lims:id="745402"><Label>(b)</Label><Text>in any other case, the system.</Text></Paragraph><ContinuedSectionSubsection lims:inforce-start-date="2017-06-02" lims:fid="745403" lims:id="745403"><Text>The owner or operator may only return the system or component, as the case may be, to service if they have made the necessary repairs to ensure that it no longer leaks.</Text></ContinuedSectionSubsection></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745404" lims:id="745404"><Label>(2)</Label><Text>Subject to subsection (4), the owner or operator of a storage tank system installed before June 12, 2008 that has single-walled underground tanks that leak a liquid must, without delay, permanently withdraw those tanks and their components from service in accordance with section <XRefInternal>44</XRefInternal> and, within two years after the later of  June 12, 2008 and the day on which the owner or operator becomes aware of the leak,</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745405" lims:id="745405"><Label>(a)</Label><Text>in the case of a storage tank system that has vertically-oriented underground tanks, remove any piping and other components that are outside the tanks in accordance with section <XRefInternal>45</XRefInternal>; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745406" lims:id="745406"><Label>(b)</Label><Text>in any other case, remove the single-walled underground tanks and their components in accordance with section <XRefInternal>45</XRefInternal>.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745407" lims:id="745407"><Label>(3)</Label><Text>Subject to subsection (4), the owner or operator of a storage tank system installed before June 12, 2008 that has single-walled underground piping and which piping leaks a liquid must, without delay,</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745408" lims:id="745408"><Label>(a)</Label><Text>temporarily withdraw that system from service in accordance with section <XRefInternal>43</XRefInternal>, permanently withdraw that piping from service in accordance with section <XRefInternal>44</XRefInternal>, remove it in accordance with section <XRefInternal>45</XRefInternal> and replace it in accordance with section <XRefInternal>14</XRefInternal>; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745409" lims:id="745409"><Label>(b)</Label><Text>permanently withdraw that system from service in accordance with section <XRefInternal>44</XRefInternal> and, within two years after the later of June 12, 2008 and the day on which the owner or operator becomes aware of the leak,</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745410" lims:id="745410"><Label>(i)</Label><Text>in the case of a storage tank system that has shop-fabricated aboveground tanks or underground tanks, other than vertically-oriented underground tanks, remove the system in accordance with section <XRefInternal>45</XRefInternal>, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745411" lims:id="745411"><Label>(ii)</Label><Text>in the case of a storage tank system that has field-erected aboveground tanks or vertically-oriented underground tanks, remove all piping and other components that are outside the tanks in accordance with section <XRefInternal>45</XRefInternal>.</Text></Subparagraph></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745412" lims:id="745412"><Label>(4)</Label><Text>If circumstances make it impossible to comply with subsection (1), (2) or (3), the owner or operator must, without delay, take necessary measures to minimize the immediate or long-term harmful effect on the environment and danger to human life or health until it becomes possible to comply with that subsection, and must, without delay, inform the Minister, in writing, of those circumstances and the measures that will be taken. For greater certainty, a petroleum product or allied petroleum product must not be transferred into the system until it becomes possible to comply with that subsection.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745414" lims:id="745414">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745415" lims:id="745415"><Label>4</Label><Text>The owner or operator of a storage tank system that permanently withdraws the system from service but that is not required to do so under subsection <XRefInternal>3</XRefInternal>(2) or (3) must</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745416" lims:id="745416"><Label>(a)</Label><Text>in the case of a storage tank system that has shop-fabricated aboveground tanks or underground tanks, other than vertically-oriented underground tanks, remove the system in accordance with section<XRefInternal>45</XRefInternal>; and</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745417" lims:id="745417"><Label>(b)</Label><Text>in the case of a storage tank system that has field-erected aboveground tanks or vertically-oriented underground tanks, remove any piping and other components that are outside the tanks in accordance with section <XRefInternal>45</XRefInternal>.</Text></Paragraph></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745418" lims:id="745418"><Label>5</Label><Text>The owner or operator of a storage tank system that has tanks designed to be installed above ground that were installed before June 12, 2008 below ground or encased within a filled secondary containment must, by June 12, 2012, permanently withdraw that system from service in accordance with section 44 and remove it in accordance with section 45.</Text><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745420" lims:id="745420">SOR/2017-110, s. 24</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745421" lims:id="745421"><Label>6</Label><Text>The owner or operator of a storage tank system that has tanks designed to be installed underground that were installed before June 12, 2008 above ground or encased within an unfilled secondary containment must, by June 12, 2012, permanently withdraw that system from service in accordance with section 44 and remove it in accordance with section 45.</Text><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745423" lims:id="745423">SOR/2017-110, s. 24</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745424" lims:id="745424"><Label>7</Label><Text>The owner or operator of a storage tank system that has a partially buried tank must, within four years after June 12, 2008, permanently withdraw that system from service in accordance with section <XRefInternal>44</XRefInternal> and remove it in accordance with section <XRefInternal>45</XRefInternal>.</Text><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745426" lims:id="745426">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745427" lims:id="745427"><Label>8</Label><Text>A person must not install a storage tank system that has either partially buried or single-walled underground tanks to store petroleum products or allied petroleum products.</Text></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745428" lims:id="745428"><Label>9</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745429" lims:id="745429"><Label>(1)</Label><Text>The owner or operator of a storage tank system installed before June 12, 2008 that has single-walled underground tanks, other than those described in subsection<XRefInternal>3</XRefInternal>(2), must, within four years after June 12, 2008, permanently withdraw those tanks and their components from service in accordance with section <XRefInternal>44</XRefInternal> and remove them in accordance with section <XRefInternal>45</XRefInternal> unless, on June 12, 2008, those tanks have</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745430" lims:id="745430"><Label>(a)</Label><Text>in the case of steel tanks, cathodic protection and leak detection, groundwater monitoring wells or vapour monitoring wells; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745431" lims:id="745431"><Label>(b)</Label><Text>in any other case, leak detection, groundwater monitoring wells or vapour monitoring wells.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745432" lims:id="745432"><Label>(2)</Label><Text>In respect of any single-walled underground tank other than a steel tank or a reinforced plastic tank, the owner or operator must, within one year after June 12, 2008, provide the Minister with a declaration, dated after June 12, 2008 and signed by a professional engineer, stating that the tank has normal and emergency venting, the walls of the tank and its floor are impervious to the passage of petroleum product or allied petroleum product, the tank’s structural integrity is maintained and the tank is suitable for the storage of petroleum products or allied petroleum products.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745434" lims:id="745434">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745435" lims:id="745435"><Label>10</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745436" lims:id="745436"><Label>(1)</Label><Text>Subject to subsection (2), the owner or operator of a storage tank system that has single-walled underground piping, other than one described in subsection <XRefInternal>3</XRefInternal>(3), that is installed before June 12, 2008 must, within four years after June 12, 2008,</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745437" lims:id="745437"><Label>(a)</Label><Text>temporarily withdraw that system from service in accordance with section <XRefInternal>43</XRefInternal>, permanently withdraw that piping from service in accordance with section <XRefInternal>44</XRefInternal>, remove it in accordance with section <XRefInternal>45</XRefInternal> and replace it in accordance with section <XRefInternal>14</XRefInternal>; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745438" lims:id="745438"><Label>(b)</Label><Text>permanently withdraw that system from service in accordance with section <XRefInternal>44</XRefInternal>, and</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745439" lims:id="745439"><Label>(i)</Label><Text>in the case of a storage tank system that has shop-fabricated aboveground tanks or underground tanks, other than vertically-oriented underground tanks, remove the system in accordance with section <XRefInternal>45</XRefInternal>, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745440" lims:id="745440"><Label>(ii)</Label><Text>in the case of a storage tank system that has field-erected aboveground tanks or vertically-oriented underground tanks, remove all piping and other components that are outside the tanks in accordance with section <XRefInternal>45</XRefInternal>.</Text></Subparagraph></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745441" lims:id="745441"><Label>(2)</Label><Text>The owner or operator is not required to comply with subsection (1) if, on June 12, 2008, that piping has</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745442" lims:id="745442"><Label>(a)</Label><Text>in the case of steel piping, cathodic protection and leak detection, groundwater monitoring wells, vapour monitoring wells, single vertical check valves or mechanical line leak detection devices; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745443" lims:id="745443"><Label>(b)</Label><Text>in the case of non-metallic or copper piping, leak detection, groundwater monitoring wells, vapour monitoring wells, single vertical check valves or mechanical line leak detection devices.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745445" lims:id="745445">SOR/2012-99, s. 21(F); SOR/2017-110, ss. 25, 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745446" lims:id="745446"><Label>11</Label><Text>The owner or operator of a storage tank system must ensure compatibility between any petroleum products and allied petroleum products to be stored in that system and the material used in the construction of the system.</Text></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745447" lims:id="745447"><Label>12</Label><Text>The owner or operator of a storage tank system must not store petroleum products or allied petroleum products in a tank of the system unless a fill pipe and vent line have been installed in that tank and all of the tank’s other openings have been sealed or connected to piping.</Text></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745448" lims:id="745448"><Label>13</Label><Text>A person must not use a secondary containment area for storage purposes.</Text><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745450" lims:id="745450">SOR/2017-110, s. 26(E)</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745451" lims:id="745451" level="1"><TitleText>Compliance with Requirements</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2025-08-28" lims:fid="745452" lims:id="745452"><Label>14</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745453" lims:id="745453"><Label>(1)</Label><Text lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536613" lims:id="1536871">The owner or operator of a storage tank system that installs the system or any component of the system on or after June 12, 2008 must ensure that the system or the component conforms to the applicable requirements set out in the following provisions of the CCME Code of Practice, subject to subsection (6.1) of this section:</Text><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745454" lims:id="1536872"><Label>(a)</Label><Text>Part 3, excluding Section 3.2, Clause 3.3.1(1)(c), Article 3.3.2, Clause 3.4.1(1)(c), Article 3.4.3, Clauses 3.5.1(1)(a) and 3.6.1(1)(l), Section 3.7, Clause 3.9.2(2)(a) and Articles 3.9.4 and 3.10.1;</Text></Paragraph><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745457" lims:id="1536873"><Label>(b)</Label><Text>Part 4, subject to the following:</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536874" lims:id="1536874"><Label>(i)</Label><Text>excluding Articles 4.2.1 to 4.2.3, Clauses 4.2.4(1)(e) and 4.2.4(2)(h), Articles 4.2.5 and 4.2.6, Sentences 4.2.8(1) to 4.3.1(1) and 4.3.6(1) to 4.3.8(1), Section 4.4, Clauses 4.5.1(1)(a), (c) and (d) and Sentences 4.5.2(1) to (4) and 4.5.3(2), and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536875" lims:id="1536875"><Label>(ii)</Label><Text>in Clause 4.5.1(1)(b),</Text><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536876" lims:id="1536876"><Label>(A)</Label><Text>the reference to “CAN/ULC-S603-1992, ‘Underground Steel Tanks’” is to be read as a reference to “CAN/ULC-S603, <XRefExternal reference-type="standard">Standard for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal>”, and</Text></Clause><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536877" lims:id="1536877"><Label>(B)</Label><Text>the reference to “CAN/ULC-S603.1-1992, ‘Galvanic Corrosion Protection Systems for Underground Steel Tanks’” is to be read as a reference to “CAN/ULC-S603.1, <XRefExternal reference-type="standard">Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal>”;</Text></Clause></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745458" lims:id="1536878"><Label>(c)</Label><Text>Part 5, subject to the following:</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536879" lims:id="1536879"><Label>(i)</Label><Text>excluding Clauses 5.2.1(1)(d) to (f), Articles 5.2.4 to 5.2.6, Clause 5.4.2(1)(b), Sentence 5.4.3(1) and Section 5.5,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536880" lims:id="1536880"><Label>(ii)</Label><Text>in Clause 5.4.2(1)(c),</Text><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536881" lims:id="1536881"><Label>(A)</Label><Text>the reference to “API RP 1632-96, ‘Cathodic Protection of Underground Storage Tank and Piping Systems’” is to be read as a reference to “API RP 1632, <XRefExternal reference-type="standard">Cathodic Protection of Underground Petroleum Storage Tanks and Piping Systems</XRefExternal>”, and</Text></Clause><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536882" lims:id="1536882"><Label>(B)</Label><Text>the reference to “API Std 2610-94, ‘Design, Construction, Operation, Maintenance and Inspection of Terminal and Tank Facilities’” is to be read as a reference to “API Std 2610, <XRefExternal reference-type="standard">Design, Construction, Operation, Maintenance, and Inspection of Terminal and Tank Facilities</XRefExternal>”, and</Text></Clause></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536883" lims:id="1536883"><Label>(iii)</Label><Text>in Clauses 5.4.4(1)(a) to (c), the references to standards are to be read as references to one of the following, whichever is in effect at the time the system or component is manufactured:</Text><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536884" lims:id="1536884"><Label>(A)</Label><Text>ULC/ORD-C971, <XRefExternal reference-type="standard">Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>,</Text></Clause><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536885" lims:id="1536885"><Label>(B)</Label><Text>CAN/ULC-S660, <XRefExternal reference-type="standard">Standard for Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>,</Text></Clause><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536886" lims:id="1536886"><Label>(C)</Label><Text>CAN/ULC-S679, <XRefExternal reference-type="standard">Standard for Metallic and Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>; and</Text></Clause></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745461" lims:id="745461"><Label>(d)</Label><Text>Section 8.6 and Article 8.7.2.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745462" lims:id="745462"><Label>(2)</Label><Text lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1273235" lims:id="1536887">The owner or operator of a storage tank system that has aboveground tanks that installs those tanks on or after June 12, 2008 must ensure that</Text><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745463" lims:id="1536888"><Label>(a)</Label><Text>the spill containment device, whether installed on the tank at the fill opening or attached to the remote fill station, bears a certification mark certifying conformity with one of the following standards, whichever is in effect at the time the storage tank system is manufactured:</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536889" lims:id="1536889"><Label>(i)</Label><Text>ULC/ORD-C142.19, <XRefExternal reference-type="standard">Spill Containment Devices for Aboveground Flammable and Combustible Liquid Storage Tanks</XRefExternal>,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536890" lims:id="1536890"><Label>(ii)</Label><Text>CAN/ULC-S663, <XRefExternal reference-type="standard">Standard for Spill Containment Devices for Flammable and Combustible Liquid Aboveground Storage Tanks</XRefExternal>,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536891" lims:id="1536891"><Label>(iii)</Label><Text>ANSI/CAN/UL/ULC 2583, <XRefExternal reference-type="standard">Standard for Safety for Fuel Tank Accessories for Flammable and Combustible Liquids</XRefExternal>; or</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745464" lims:id="745464"><Label>(b)</Label><Text lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536614" lims:id="1536892">the tank is equipped with a spill containment device and bears a certification mark certifying conformity with one of the following standards:</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745465" lims:id="1536893"><Label>(i)</Label><Text>CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal>,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745466" lims:id="1536895"><Label>(ii)</Label><Text>CAN/ULC 653, <XRefExternal reference-type="standard">Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids</XRefExternal>,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745467" lims:id="1536896"><Label>(iii)</Label><Text>ULC/ORD-C142.5, <XRefExternal reference-type="standard">Concrete Encased Steel Aboveground Tank Assemblies for Flammable and Combustible Liquids</XRefExternal>, or CAN/ULC 677, <XRefExternal reference-type="standard">Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745468" lims:id="1273245"><Label>(iv)</Label><Text>ULC/ORD-C142.18, <XRefExternal reference-type="standard">Rectangular Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal>, or CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745469" lims:id="1536897"><Label>(v)</Label><Text>ULC/ORD-C142.21, <XRefExternal reference-type="standard">Aboveground Used Oil Systems</XRefExternal>, or CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745470" lims:id="1273246"><Label>(vi)</Label><Text>ULC/ORD-C142.22, <XRefExternal reference-type="standard">Contained Vertical Steel Aboveground Tank Assemblies for Flammable and Combustible Liquids</XRefExternal>, or CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured.</Text></Subparagraph></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745471" lims:id="745471"><Label>(3)</Label><Text>The owner or operator of a storage tank system that has underground tanks that installs those tanks on or after June 12, 2008 must ensure that those tanks bear a certification mark certifying conformity with one of the following standards:</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745472" lims:id="745472"><Label>(a)</Label><Text>for underground steel tanks</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745473" lims:id="1536898"><Label>(i)</Label><Text>if used for storing used oil, CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal>, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745474" lims:id="745474"><Label>(ii)</Label><Text>if used for storing other petroleum products or allied petroleum products</Text><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745475" lims:id="1536899"><Label>(A)</Label><Text>CAN/ULC-S603, <XRefExternal reference-type="standard">Standard for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal>, or</Text></Clause><Clause lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745476" lims:id="1536900"><Label>(B)</Label><Text>CAN/ULC-S603.1, <XRefExternal reference-type="standard">Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal>;</Text></Clause></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745477" lims:id="745477"><Label>(b)</Label><Text>for underground reinforced plastic tanks</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745478" lims:id="1536901"><Label>(i)</Label><Text>if used for storing used oil, CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal>, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745479" lims:id="1536902"><Label>(ii)</Label><Text>if used for storing other petroleum products or allied petroleum products, CAN/ULC-S615, <XRefExternal reference-type="standard">Standard for Fibre Reinforced Plastic Underground Tanks for Flammable and Combustible Liquids</XRefExternal>, or ANSI/CAN/UL/ULC 1316, <XRefExternal reference-type="standard">Standard for Fibre Reinforced Underground Tanks for Flammable and Combustible Liquid</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured; and</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745480" lims:id="1273248"><Label>(c)</Label><Text>for underground tanks that are double containment linings, ULC/ORD-C58.4, <XRefExternal reference-type="standard">Double Containment Fibre Reinforced Plastic Linings for Flammable and Combustible Liquid Storage Tanks</XRefExternal>, or CAN/ULC-S669, <XRefExternal reference-type="standard">Standard for Internal Retrofit Systems for Underground Tanks for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745481" lims:id="745481"><Label>(4)</Label><Text>The owner or operator of a storage tank system that has steel underground tanks that installs those tanks on or after June 12, 2008 must ensure that those tanks are protected from corrosion as follows:</Text><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745482" lims:id="1536903"><Label>(a)</Label><Text>those tanks must bear a certification mark certifying conformity with CAN/ULC-S603.1, <XRefExternal reference-type="standard">Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal>; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745483" lims:id="745483"><Label>(b)</Label><Text>those tanks must have a cathodic protection system designed by a corrosion expert.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745484" lims:id="745484"><Label>(5)</Label><Text>The owner or operator of a storage tank system that installs piping on or after June 12, 2008 must ensure that</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745485" lims:id="745485"><Label>(a)</Label><Text>the piping does not have buried or concealed mechanical joints; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745486" lims:id="745486"><Label>(b)</Label><Text>any piping other than copper piping bears a certification mark certifying conformity with</Text><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745487" lims:id="1536904"><Label>(i)</Label><Text>one of the standards referred to in Clauses 5.2.1(1)(a) to (c) and (g) of the CCME Code of Practice, subject to subsection (6.1) of this section, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="745488" lims:id="1536905"><Label>(ii)</Label><Text>ULC/ORD-C971, <XRefExternal reference-type="standard">Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>, CAN/ULC-S660, <XRefExternal reference-type="standard">Standard for Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>, or CAN/ULC-S679, <XRefExternal reference-type="standard">Standard for Metallic and Nonmetallic Underground Piping for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured.</Text></Subparagraph></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745489" lims:id="745489"><Label>(6)</Label><Text>Any reference to a standard in this section is a reference to the version of that standard that is in effect at the time the storage tank system’s component is erected or manufactured, as applicable.</Text></Subsection><Subsection lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536868" lims:id="1536868"><Label>(6.1)</Label><Text>For the purposes of subsections (1) and (5), any reference to a standard in the provisions of the CCME Code of Practice set out in column 1 of Schedule 4 is to be read as a reference to</Text><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536869" lims:id="1536869"><Label>(a)</Label><Text>if only one standard is set out in column 2, the standard that is set out in that column; or</Text></Paragraph><Paragraph lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536870" lims:id="1536870"><Label>(b)</Label><Text>if more than one standard is set out in column 2, any one of those standards, whichever is in effect at the time the storage tank system’s component is erected or manufactured.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745490" lims:id="745490"><Label>(7)</Label><Text>The owner or operator of a storage tank system must comply with the applicable requirements before any petroleum products or allied petroleum products are first transferred into that system.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745492" lims:id="745492">SOR/2012-99, s. 22; SOR/2017-110, s. 27</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273240" lims:id="1273240" lims:enactId="1272355">SOR/2020-235, s. 2</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536867" lims:id="1536867" lims:enactId="1536151">SOR/2025-167, s. 1</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745493" lims:id="745493"><Label>15</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745494" lims:id="745494"><Label>(1)</Label><Text>The owner or operator of a storage tank system must ensure that petroleum product and allied petroleum product transfer areas are designed to contain any releases in liquid form in the environment that occur during the transfer process.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745495" lims:id="745495"><Label>(2)</Label><Text>Subsection (1) applies to storage tank systems installed before June 12, 2008 four years after June 12, 2008.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745497" lims:id="745497">SOR/2017-110, ss. 28, 37</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745498" lims:id="745498" level="1"><TitleText>Leak Detection</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745499" lims:id="745499"><Label>16</Label><Text>The owner or operator of a storage tank system installed before June 12, 2008 that has single-walled underground tanks must test those tanks using a tank precision leak detection test in accordance with section <XRefInternal>21</XRefInternal> within two years after June 12, 2008 and after that test they must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745500" lims:id="745500"><Label>(a)</Label><Text>immediately</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745501" lims:id="745501"><Label>(i)</Label><Text>use automatic tank gauging in accordance with section <XRefInternal>18</XRefInternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745502" lims:id="745502"><Label>(ii)</Label><Text>use continuous in-tank leak detection in accordance with section <XRefInternal>20</XRefInternal>; or</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745503" lims:id="745503"><Label>(b)</Label><Text>annually perform a tank precision leak detection test in accordance with section <XRefInternal>21</XRefInternal>.</Text></Paragraph><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745505" lims:id="745505">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745506" lims:id="745506"><Label>17</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745507" lims:id="745507"><Label>(1)</Label><Text>The owner or operator of a storage tank system installed before June 12, 2008 that has single-walled underground piping must test that piping using a piping precision leak detection test in accordance with section <XRefInternal>24</XRefInternal> within two years after June 12, 2008 and after that test they must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745508" lims:id="745508"><Label>(a)</Label><Text>immediately</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745509" lims:id="745509"><Label>(i)</Label><Text>use continuous external underground pipe leak monitoring,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745510" lims:id="745510"><Label>(ii)</Label><Text>use automatic tank gauging in accordance with section <XRefInternal>18</XRefInternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745511" lims:id="745511"><Label>(iii)</Label><Text>use continuous in-tank leak detection in accordance with section <XRefInternal>20</XRefInternal>; or</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745512" lims:id="745512"><Label>(b)</Label><Text>annually perform a piping precision leak detection test in accordance with section <XRefInternal>24</XRefInternal>.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745513" lims:id="745513"><Label>(2)</Label><Text>The continuous external underground pipe leak monitoring must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745514" lims:id="745514"><Label>(a)</Label><Text>be carried out using a sensor cable system designed for installation adjacent to the piping and within the same pipe trench;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745515" lims:id="745515"><Label>(b)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within 96 hours after the onset of the leak at the lowest expected soil temperature at the site where the sensor cable system is installed;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745516" lims:id="745516"><Label>(c)</Label><Text>be capable of locating the leak with an accuracy of ± 1 m;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745517" lims:id="745517"><Label>(d)</Label><Text>be capable of continuously monitoring sensor cable system integrity; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745518" lims:id="745518"><Label>(e)</Label><Text>have an alarm located at a place of work where it can be readily heard and seen.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745520" lims:id="745520">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:lastAmendedDate="2020-10-26" lims:fid="745521" lims:id="1273251"><Label>18</Label><Text>Any reference to a standard in this section is a reference to the version of that standard that is in effect at the time of the certification. Equipment used for automatic tank gauging referred to in subparagraphs 16(a)(i) and 17(1)(a)(ii) must have an alarm located at a place of work where it can be readily heard and seen and must bear a certification mark certifying conformity with</Text><Paragraph lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273252" lims:id="1273252"><Label>(a)</Label><Text>ULC/ORD-C58.12, <XRefExternal reference-type="standard">Leak Detection Devices (Volumetric Type) for Underground Flammable Liquid Storage Tanks</XRefExternal>, or CAN/ULC-S675.1, <XRefExternal reference-type="standard">Standard for Volumetric Leak Detection Devices for Underground and Aboveground Storage Tanks for Flammable and Combustible Liquid</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured; or</Text></Paragraph><Paragraph lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273253" lims:id="1273253"><Label>(b)</Label><Text>ULC/ORD-C58.14, <XRefExternal reference-type="standard">Nonvolumetric Leak Detection Devices for Underground Flammable Liquid Storage Tanks,</XRefExternal> or CAN/ULC-S675.2, <XRefExternal reference-type="standard">Standard for Nonvolumetric Precision Leak Detection Devices for Underground and Aboveground Storage Tanks and Piping for Flammable and Combustible Liquids</XRefExternal>, whichever is in effect at the time the storage tank system is manufactured.</Text></Paragraph><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745525" lims:id="745525">SOR/2017-110, s. 29</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273250" lims:id="1273250" lims:enactId="1272370">SOR/2020-235, s. 3</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745526" lims:id="745526"><Label>19</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745527" lims:id="745527"><Label>(1)</Label><Text>The owner or operator of a storage tank system installed before June 12, 2008 that has horizontal aboveground tanks without secondary containment must visually inspect the walls of those tanks within two years after June 12, 2008 to determine if the tank is leaking and after that inspection they must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745528" lims:id="745528"><Label>(a)</Label><Text>visually inspect the walls of those tanks at least once per month and perform an inventory reconciliation in accordance with subsection (2);</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745529" lims:id="745529"><Label>(b)</Label><Text>immediately</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745530" lims:id="745530"><Label>(i)</Label><Text>use continuous in-tank leak detection in accordance with section <XRefInternal>20</XRefInternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745531" lims:id="745531"><Label>(ii)</Label><Text>use continuous external horizontal aboveground tank leak monitoring; or</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745532" lims:id="745532"><Label>(c)</Label><Text>annually perform a tank precision leak detection test in accordance with section <XRefInternal>21</XRefInternal>.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745533" lims:id="745533"><Label>(2)</Label><Text>The inventory reconciliation must include</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745534" lims:id="745534"><Label>(a)</Label><Text>the measurement of the level of water and the combined level of water and petroleum product or allied petroleum product in every storage tank of the storage tank system at least every seven days unless the storage tank system is located at a fuel dispensing station, in which case the levels must be measured each day the station is in operation; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745535" lims:id="745535"><Label>(b)</Label><Text>a comparison of the measurements with readings of any meters that measure the volume of liquid transferred and the calculation of any gain or loss of liquid each time the measurements are taken.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745536" lims:id="745536"><Label>(3)</Label><Text>The continuous external horizontal aboveground tank leak monitoring must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745537" lims:id="745537"><Label>(a)</Label><Text>be carried out using a sensor cable system designed for installation beneath the horizontal aboveground tank and surrounding its perimeter dripline in order that any leak will be detected before any liquid moves beyond the tank’s perimeter;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745538" lims:id="745538"><Label>(b)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within 30 days after the onset of the leak at the lowest expected air temperature at the site where the sensor cable system is installed;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745539" lims:id="745539"><Label>(c)</Label><Text>be capable of locating the leak with an accuracy of ± 1 m;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745540" lims:id="745540"><Label>(d)</Label><Text>be capable of continuously monitoring sensor cable system integrity; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745541" lims:id="745541"><Label>(e)</Label><Text>have an alarm located at a place of work where it can be readily heard and seen.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745543" lims:id="745543">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745544" lims:id="745544"><Label>20</Label><Text>Continuous in-tank leak detection referred to in subparagraphs <XRefInternal>16</XRefInternal>(a)(ii), <XRefInternal>17</XRefInternal>(1)(a)(iii), <XRefInternal>19</XRefInternal>(1)(b)(i) and <XRefInternal>22</XRefInternal>(1)(a)(i) must conform to the requirements set out in Article 6.2.6 of the CCME Code of Practice and have an alarm located at a place of work where it can be readily heard and seen.</Text></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745545" lims:id="745545"><Label>21</Label><Text>The tank precision leak detection test referred to in section <XRefInternal>16</XRefInternal> and paragraphs <XRefInternal>19</XRefInternal>(1)(c), <XRefInternal>26</XRefInternal>(a) and <XRefInternal>43</XRefInternal>(b) must</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745546" lims:id="745546"><Label>(a)</Label><Text>be capable of measuring the level of water in the tank to within 3 mm with a probability of 0.95 or greater;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745547" lims:id="745547"><Label>(b)</Label><Text>if a volumetric method is used, be capable of measuring the level of liquid in the tank to within 3 mm with a probability of 0.99 or greater;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745548" lims:id="745548"><Label>(c)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within a 24 hour period with a probability of detection of 0.95 or greater and a probability of false alarm of 0.05 or less, accounting for variables such as vapour pockets, thermal expansion and contraction, evaporation and condensation, temperature stratification, groundwater level and tank deformation; and</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745549" lims:id="745549"><Label>(d)</Label><Text>be performed, using a documented and validated method, by an individual trained in the maintenance and use of the test equipment.</Text></Paragraph></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2020-10-26" lims:fid="745550" lims:id="745550"><Label>22</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745551" lims:id="745551"><Label>(1)</Label><Text>Subject to subsections (5) and (6), the owner or operator of a storage tank system installed before June 12, 2008 that has vertical aboveground tanks without secondary containment must, within two years after June 12, 2008, inspect those tanks or the floor of those tanks, and after that inspection they must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745552" lims:id="745552"><Label>(a)</Label><Text>immediately</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745553" lims:id="745553"><Label>(i)</Label><Text>use continuous in-tank leak detection in accordance with section <XRefInternal>20</XRefInternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745554" lims:id="745554"><Label>(ii)</Label><Text>use continuous external vertical aboveground tank leak monitoring for each of those tanks; or</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745555" lims:id="745555"><Label>(b)</Label><Text>once every ten years, inspect those tanks or the floor of those tanks.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745556" lims:id="1273260"><Label>(2)</Label><Text>The inspection of the vertical aboveground tanks must be performed in accordance with the version of API Standard 653, <XRefExternal reference-type="standard">Tank Inspection, Repair, Alteration, and Reconstruction</XRefExternal> that is in effect at the time of the inspection.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745557" lims:id="745557"><Label>(3)</Label><Text>The inspection of the floor of the vertical aboveground tank must be performed</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745558" lims:id="745558"><Label>(a)</Label><Text>using one of the following testing methods, namely, ultrasonic, magnetic particle, videographic or vacuum; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745559" lims:id="745559"><Label>(b)</Label><Text>using a documented and validated method by an individual trained in the maintenance and use of the test equipment.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745560" lims:id="745560"><Label>(4)</Label><Text>The continuous external vertical aboveground tank leak monitoring must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745561" lims:id="745561"><Label>(a)</Label><Text>be a sensor cable system designed for installation beneath the floor plate of the vertical aboveground tank in order to detect any leak into the soil beneath the tank floor and immediately surrounding the tank’s perimeter;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745562" lims:id="745562"><Label>(b)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within 30 days after the onset of the leak at the lowest expected soil temperature at the site where the sensor cable system is installed;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745563" lims:id="745563"><Label>(c)</Label><Text>be capable of locating the leak with an accuracy of ± 1 m;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745564" lims:id="745564"><Label>(d)</Label><Text>be capable of continuously monitoring sensor cable system integrity; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745565" lims:id="745565"><Label>(e)</Label><Text>have an alarm located at a place of work where it can be readily heard and seen.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745566" lims:id="745566"><Label>(5)</Label><Text>If, within eight years before June 12, 2008, the owner or operator has inspected the vertical aboveground tanks without secondary containment in accordance with the version of API Standard 653, <XRefExternal reference-type="standard">Tank Inspection, Repair, Alteration, and Reconstruction</XRefExternal> that existed at the time of the inspection, they must perform a new inspection in accordance with subsection (2) at least every ten years after the day on which that inspection was performed.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745567" lims:id="745567"><Label>(6)</Label><Text>If, within eight years before June 12, 2008, the owner or operator has inspected the floor of the vertical aboveground tanks without secondary containment as set out in subsection (3), they must perform a new inspection in accordance with that subsection at least every ten years after the day on which that inspection was performed.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745569" lims:id="745569">SOR/2017-110, s. 37</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273261" lims:id="1273261" lims:enactId="1272372">SOR/2020-235, s. 4</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745570" lims:id="745570"><Label>23</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745571" lims:id="745571"><Label>(1)</Label><Text>The owner or operator of a storage tank system installed before June 12, 2008 that has aboveground piping without secondary containment must visually inspect the walls of that piping within two years after June 12, 2008 to determine if the piping is leaking and after that inspection they must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745572" lims:id="745572"><Label>(a)</Label><Text>immediately</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745573" lims:id="745573"><Label>(i)</Label><Text>use continuous external aboveground pipe leak monitoring for that piping, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745574" lims:id="745574"><Label>(ii)</Label><Text>implement a corrosion analysis program for that piping, developed and conducted by a corrosion expert, that includes at least an annual inspection;</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745575" lims:id="745575"><Label>(b)</Label><Text>once each month, visually inspect that piping; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745576" lims:id="745576"><Label>(c)</Label><Text>annually perform a piping precision leak detection test of that piping in accordance with section <XRefInternal>24</XRefInternal>.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745577" lims:id="745577"><Label>(2)</Label><Text>The continuous external aboveground pipe leak monitoring must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745578" lims:id="745578"><Label>(a)</Label><Text>be carried out using a sensor cable system designed either for installation on the bottom of the piping or for placement on the ground underneath the piping;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745579" lims:id="745579"><Label>(b)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within 96 hours after the onset of the leak at the lowest expected soil temperature at the site where the sensor cable system is installed;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745580" lims:id="745580"><Label>(c)</Label><Text>be capable of locating the leak with an accuracy of ± 1 m;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745581" lims:id="745581"><Label>(d)</Label><Text>be capable of continuously monitoring sensor cable system integrity; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745582" lims:id="745582"><Label>(e)</Label><Text>have an alarm located at a place of work where it can be readily heard and seen.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745584" lims:id="745584">SOR/2017-110, s. 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745585" lims:id="745585"><Label>24</Label><Text>The piping precision leak detection test referred to in section <XRefInternal>17</XRefInternal> and paragraphs <XRefInternal>23</XRefInternal>(1)(c) and <XRefInternal>26</XRefInternal>(d) must</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745586" lims:id="745586"><Label>(a)</Label><Text>be capable of detecting a leak rate of at least 0.38 L/h within a 24 hour period at a line pressure of 310 kPa with a probability of detection of 0.95 or greater and a probability of false alarm of 0.05 or less, accounting for variables such as vapour pockets, thermal expansion and contraction, static head pressure, temperature differential and piping compressibility; and</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745587" lims:id="745587"><Label>(b)</Label><Text>be performed, using a documented and validated method, by an individual trained in the maintenance and use of the test equipment.</Text></Paragraph></Section><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745588" lims:id="745588"><Label>25</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745589" lims:id="745589"><Label>(1)</Label><Text>The owner or operator of a storage tank system that has turbine, transition, dispenser or pump sumps must, by June 12, 2010, visually inspect those sumps to determine if they are leaking and after that inspection they must either</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745590" lims:id="745590"><Label>(a)</Label><Text>immediately use continuous sump leak monitoring for those sumps; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745591" lims:id="745591"><Label>(b)</Label><Text>visually inspect those sumps annually.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745592" lims:id="745592"><Label>(2)</Label><Text>The continuous sump leak monitoring must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745593" lims:id="745593"><Label>(a)</Label><Text>use a petroleum product probe capable of detecting 1 mm of petroleum product or allied petroleum product on a concrete surface or 1 mm of petroleum product or allied petroleum product floating on the water within the sump; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745594" lims:id="745594"><Label>(b)</Label><Text>have a probe that is capable of reporting the presence of petroleum product or allied petroleum product at the probe location within two hours of contact with that product at the lowest expected air temperature at the site where the probe is installed.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745596" lims:id="745596">SOR/2017-110, s. 30</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2012-05-04" lims:lastAmendedDate="2012-05-04" lims:fid="745597" lims:id="745597"><Label>26</Label><Text>In the case of a storage tank system that is not equipped with continuous leak monitoring, if the owner or operator of the storage tank system has reasonable grounds to believe that any of the following components of the system is leaking, they must test or inspect the component as follows:</Text><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745598" lims:id="745598"><Label>(a)</Label><Text>in the case of an underground tank, they must test that tank using the tank precision leak detection test in accordance with section <XRefInternal>21</XRefInternal>;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745599" lims:id="745599"><Label>(b)</Label><Text>in the case of an aboveground vertical tank, they must inspect the tank in accordance with subsection <XRefInternal>22</XRefInternal>(2) or the floor of that tank in accordance with subsection <XRefInternal>22</XRefInternal>(3);</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745600" lims:id="745600"><Label>(c)</Label><Text>in the case of an aboveground horizontal tank, they must visually inspect the walls of that tank to determine if the tank is leaking;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745601" lims:id="745601"><Label>(d)</Label><Text>in the case of underground piping, they must test that piping using the piping precision leak detection test in accordance with section <XRefInternal>24</XRefInternal>;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745602" lims:id="745602"><Label>(e)</Label><Text>in the case of aboveground piping, they must visually inspect the walls of that piping to determine if the piping is leaking; or</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745603" lims:id="745603"><Label>(f)</Label><Text>in the case of a turbine, transition, dispenser or pump sump, they must perform a static liquid media leak detection test that respects the following conditions:</Text><Subparagraph lims:inforce-start-date="2012-05-04" lims:fid="745604" lims:id="745604"><Label>(i)</Label><Text>the test has a duration of at least one hour,</Text></Subparagraph><Subparagraph lims:inforce-start-date="2012-05-04" lims:fid="745605" lims:id="745605"><Label>(ii)</Label><Text>the level of the test liquid exceeds the elevation of the sump’s piping and of other points of entry into the sump, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2012-05-04" lims:fid="745606" lims:id="745606"><Label>(iii)</Label><Text>there is no measurable loss of liquid in the sump.</Text></Subparagraph></Paragraph><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2012-05-04" lims:fid="745608" lims:id="745608">SOR/2012-99, s. 23(F)</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2012-05-04" lims:lastAmendedDate="2012-05-04" lims:fid="745609" lims:id="745609"><Label>27</Label><Text>The owner or operator of a storage tank system that has tested or inspected any component of the system for leaks under sections <XRefInternal>16</XRefInternal> to <XRefInternal>26</XRefInternal> must keep a record that includes the following information:</Text><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745610" lims:id="745610"><Label>(a)</Label><Text>the test or inspection date;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745611" lims:id="745611"><Label>(b)</Label><Text>the storage tank system identification number;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745612" lims:id="745612"><Label>(c)</Label><Text>the allied petroleum product or the type of petroleum product stored in the system;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745613" lims:id="745613"><Label>(d)</Label><Text>the test or inspection results;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745614" lims:id="745614"><Label>(e)</Label><Text>the testing method;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745615" lims:id="745615"><Label>(f)</Label><Text>the name and address of the individual and, if applicable, the company that performed the test or inspection; and</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745616" lims:id="745616"><Label>(g)</Label><Text>the components of the corrosion analysis program referred to in subparagraph <XRefInternal>23</XRefInternal>(1)(a)(ii).</Text></Paragraph><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2012-05-04" lims:fid="745618" lims:id="745618">SOR/2012-99, s. 24</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745619" lims:id="745619" level="1"><TitleText>Identification of Storage Tank Systems</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745620" lims:id="745620"><Label>28</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745621" lims:id="745621"><Label>(1)</Label><Text>The owner of a storage tank system that is installed before June 12, 2008 must identify the system by submitting to the Minister, in writing, the information set out in Schedule 2</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745622" lims:id="745622"><Label>(a)</Label><Text>by June 12, 2009; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745623" lims:id="745623"><Label>(b)</Label><Text>by June 12, 2010 if they submit to the Minister a storage tank system identification progress report containing the information set out in Schedule 3 by June 12, 2009.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745624" lims:id="745624"><Label>(2)</Label><Text>The owner of a storage tank system that is installed on or after June 12, 2008 must identify the system by submitting to the Minister, in writing, the information set out in Schedule 2 before the day on which the first transfer of petroleum products or allied petroleum products into any tank of the system occurs.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745625" lims:id="745625"><Label>(3)</Label><Text>The Minister must issue an identification number for the storage tank system for which the information was submitted and inform the owner of the identification number and its date of issuance.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745626" lims:id="745626"><Label>(4)</Label><Text>The owner or operator must display the identification number in a readily visible location on or near the storage tank system for which the number was issued.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745627" lims:id="745627"><Label>(5)</Label><Text>The owner or operator must update the information submitted under subsection (1) or (2) and submit to the Minister, in writing, any changed information within 60 days after the change.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745628" lims:id="745628"><Label>(6)</Label><Text>A person must not operate a storage tank system unless an identification number has been issued for that system. In the case of a storage tank system referred to in subsection (1), this subsection applies beginning June 12, 2010.</Text></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745629" lims:id="745629"><Label>(7)</Label><Text>The person that is required to submit information under subsection (1), (2) or (5) must also submit to the Minister, in writing, a certification that the information is accurate and complete, dated and signed by the person or a person authorized to act on their behalf.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745631" lims:id="745631">SOR/2017-110, s. 31</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745632" lims:id="745632" level="1"><TitleText>Delivery of Petroleum Products or Allied Petroleum Products</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745633" lims:id="745633"><Label>29</Label><Text>A person that delivers petroleum products or allied petroleum products must comply with the following requirements:</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745634" lims:id="745634"><Label>(a)</Label><Text>they must immediately notify the operator of the storage tank system of any release in liquid form in the environment that occurs during the transfer or any evidence observed of a leak or of any release in liquid form; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745635" lims:id="745635"><Label>(b)</Label><Text>beginning two years after June 12, 2008,</Text><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745636" lims:id="745636"><Label>(i)</Label><Text>they must not transfer petroleum products or allied petroleum products into any storage tank system unless the storage tank system identification number is visible, and</Text></Subparagraph><Subparagraph lims:inforce-start-date="2017-06-02" lims:fid="745637" lims:id="745637"><Label>(ii)</Label><Text>they must keep a record of the storage tank system identification number.</Text></Subparagraph></Paragraph><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745639" lims:id="745639">SOR/2017-110, ss. 32, 37</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745640" lims:id="745640" level="1"><TitleText>Emergency Plan</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745641" lims:id="745641"><Label>30</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745642" lims:id="745642"><Label>(1)</Label><Text>The owner or operator of a storage tank system must prepare an emergency plan taking into consideration the following factors:</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745643" lims:id="745643"><Label>(a)</Label><Text>the properties and characteristics of each petroleum product or allied petroleum product stored in each tank of the system and the maximum expected quantity of the petroleum product or allied petroleum product to be stored in the system at any time during any calendar year; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745644" lims:id="745644"><Label>(b)</Label><Text>the characteristics of the place where the system is located and of the surrounding area that may increase the risk of harm to the environment or of danger to human life or health.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745645" lims:id="745645"><Label>(2)</Label><Text>The emergency plan must include</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745646" lims:id="745646"><Label>(a)</Label><Text>a description of the factors considered under subsection (1);</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745647" lims:id="745647"><Label>(b)</Label><Text>a description of the measures to be used to prevent, warn of, prepare for, respond to and recover from any emergency that may cause harm to the environment or danger to human life or health;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745648" lims:id="745648"><Label>(c)</Label><Text>a list of the individuals who are required to carry out the plan and a description of their roles and responsibilities;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745649" lims:id="745649"><Label>(d)</Label><Text>the identification of the training required for each of the individuals listed under paragraph (c);</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745650" lims:id="745650"><Label>(e)</Label><Text>a list of the emergency response equipment included as part of the plan, and the equipment’s location; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745651" lims:id="745651"><Label>(f)</Label><Text>the measures to be taken to notify members of the public who may be adversely affected by the harm or danger referred to in paragraph (b).</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745652" lims:id="745652"><Label>(3)</Label><Text>The owner or operator of a storage tank system must ensure that the emergency plan is ready to be implemented</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745653" lims:id="745653"><Label>(a)</Label><Text>in the case of a storage tank system that is installed before June 12, 2008, no later than two years after June 12, 2008; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745654" lims:id="745654"><Label>(b)</Label><Text>in any other case, before the day on which the first transfer of petroleum products or allied petroleum products into any tank of the storage tank system occurs.</Text></Paragraph></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745656" lims:id="745656">SOR/2012-99, s. 25(E); SOR/2017-110, ss. 33(E), 37</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745657" lims:id="745657"><Label>31</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745658" lims:id="745658"><Label>(1)</Label><Text>The owner or operator of a storage tank system must keep the emergency plan up-to-date and keep a copy of it readily available for the individuals who are required to carry it out, as well as a copy at the place where the storage tank system is located if that place is a place of work.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745659" lims:id="745659"><Label>(2)</Label><Text>The owner or operator must notify the Minister of the civic address of each location where the emergency plan is kept.</Text></Subsection></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745660" lims:id="745660"><Label>32</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745661" lims:id="745661"><Label>(1)</Label><Text>If the owner or operator of a storage tank system has prepared an emergency plan with respect to the system on a voluntary basis or for another government or under an Act of Parliament and the plan meets the requirements of subsections <XRefInternal>30</XRefInternal>(1) and (2), they may use that plan for the purposes of meeting those requirements.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745662" lims:id="745662"><Label>(2)</Label><Text>If the plan does not meet all of the requirements of subsections <XRefInternal>30</XRefInternal>(1) and (2), the owner or operator may use the plan if they amend it so that it meets all of those requirements.</Text></Subsection></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745663" lims:id="745663" level="1"><TitleText>Installation of Storage Tank Systems</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745664" lims:id="745664"><Label>33</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745665" lims:id="745665"><Label>(1)</Label><Text>The owner of a storage tank system must have the system installed by a person approved to do so by the province in which the system is to be installed. If no person has been approved in the province where the storage tank system is to be installed, the installation must be supervised by a professional engineer.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745666" lims:id="745666"><Label>(2)</Label><Text>The owner or operator must keep a record establishing that the storage tank system was installed by an approved person or that the installation was supervised by a professional engineer.</Text></Subsection></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745667" lims:id="745667"><Label>34</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745668" lims:id="745668"><Label>(1)</Label><Text>For the installation of any storage tank system, the owner of the system must use design plans, drawings and specifications of the system that bear the stamp and signature of a professional engineer.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745669" lims:id="745669"><Label>(2)</Label><Text>Upon the installation and before the first transfer of any petroleum products or allied petroleum products into any tank of the storage tank system, the owner of the system must ensure that as-built drawings are prepared, bear the stamp and signature of a professional engineer and show</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745670" lims:id="745670"><Label>(a)</Label><Text>the outline of all tanks;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745671" lims:id="745671"><Label>(b)</Label><Text>the centreline of all piping;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745672" lims:id="745672"><Label>(c)</Label><Text>the centreline of all underground electrical power and monitor sensor conduits;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745673" lims:id="745673"><Label>(d)</Label><Text>the building foundation outlines;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745674" lims:id="745674"><Label>(e)</Label><Text>the property lines; and</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745675" lims:id="745675"><Label>(f)</Label><Text>the secondary containment systems.</Text></Paragraph></Subsection></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745676" lims:id="745676" level="1"><TitleText>Operation and Maintenance</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745677" lims:id="745677"><Label>35</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745678" lims:id="745678"><Label>(1)</Label><Text>If the owner or operator of a storage tank system uses an oil-water separator in the operation of the system, the operator must</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745679" lims:id="745679"><Label>(a)</Label><Text>each month, measure, as close to the baffle as possible, the thickness of the free oil layer and the separated solids layer and keep a record of those measurements with the date of measurement; or</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745680" lims:id="745680"><Label>(b)</Label><Text>use an oil-water separator that is electronically monitored.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745681" lims:id="745681"><Label>(2)</Label><Text>If the owner or operator becomes aware of a leak in the storage tank system or a release in liquid form in the environment, they must, without delay, measure the thickness of the free oil layer and the separated solids layer in the oil-water separator and keep a record of that measurement.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745683" lims:id="745683">SOR/2017-110, s. 34</HistoricalNoteSubItem></HistoricalNote></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745684" lims:id="745684"><Label>36</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745685" lims:id="745685"><Label>(1)</Label><Text>If the owner or operator of a storage tank system uses an oil-water separator in the operation of the system, the operator must ensure that the oil-water separator’s free oil layer is removed</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745686" lims:id="745686"><Label>(a)</Label><Text>continuously by an automatic skimmer; or</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745687" lims:id="745687"><Label>(b)</Label><Text>in a manner such that the thickness of the layer does not exceed 50 mm.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745688" lims:id="745688"><Label>(2)</Label><Text>The owner or operator must ensure that disposal of the free oil removed occurs in a manner such that there will be no immediate or long-term harmful effect on the environment and the disposal will not constitute a danger to human life or health, and must keep a record of the quantity disposed of, the disposal method and the place where the free oil was disposed of.</Text></Subsection></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745689" lims:id="745689"><Label>37</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745690" lims:id="745690"><Label>(1)</Label><Text>If the owner or operator of a storage tank system uses an oil-water separator in the operation of the system, the operator must ensure that the oil-water separator’s separated solids layer is removed</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745691" lims:id="745691"><Label>(a)</Label><Text>by an automatic removal device; or</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745692" lims:id="745692"><Label>(b)</Label><Text>in a manner such that the thickness of the layer does not exceed 150 mm.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745693" lims:id="745693"><Label>(2)</Label><Text>The owner or operator must ensure that disposal of the separated solids removed occurs in a manner such that there will be no immediate or long-term harmful effect on the environment and the disposal will not constitute a danger to human life or health, and must keep a record of the quantity disposed of, the disposal method and the place where the separated solids were disposed of.</Text></Subsection></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745694" lims:id="745694"><Label>38</Label><Text>If the owner or operator of a storage tank system uses an oil-water separator in the operation of the system, the operator must ensure that the oil-water separator’s water is discharged in a manner such that there will be no immediate or long-term harmful effect on the environment and will not constitute a danger to human life or health.</Text></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745695" lims:id="745695"><Label>39</Label><Text>The owner or operator of a storage tank system must not use centrifugal-type pumps to transfer oil-contaminated water from dikes or sumps to the oil-water separator.</Text></Section><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745696" lims:id="745696"><Label>40</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745697" lims:id="745697"><Label>(1)</Label><Text>The owner or operator of a storage tank system must ensure that disposal of water that accumulates in the bottom of any tank of the system occurs in a manner such that there will be no immediate or long-term harmful effect on the environment and the disposal will not constitute a danger to human life or health.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745698" lims:id="745698"><Label>(2)</Label><Text>The owner or operator of the storage tank system must keep a record of the quantity of any tank bottom water removed, the date of its removal, the name and address of the individual and, if applicable, the company removing it, the disposal method and the place where it was disposed of.</Text></Subsection></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745699" lims:id="745699" level="1"><TitleText>Release Report</TitleText></Heading><Section lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2017-06-02" lims:fid="745700" lims:id="745700"><Label>41</Label><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745701" lims:id="745701"><Label>(1)</Label><Text>For the purposes of paragraph 212(1)(a) of the <XRefExternal reference-type="act" link="C-15.31">Canadian Environmental Protection Act, 1999</XRefExternal>, the written report must contain the following information:</Text><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745702" lims:id="745702"><Label>(a)</Label><Text>the names of both the owner and the operator of the storage tank system;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745703" lims:id="745703"><Label>(b)</Label><Text>the identification number of the storage tank system;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745704" lims:id="745704"><Label>(c)</Label><Text>the date on which any release in liquid form in the environment occurred;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745705" lims:id="745705"><Label>(d)</Label><Text>each allied petroleum product or type of petroleum product that is the subject of the report;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745706" lims:id="745706"><Label>(e)</Label><Text>the quantity of each petroleum product or allied petroleum product that is the subject of the report or, if the quantity cannot be determined, an estimate of that quantity;</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745707" lims:id="745707"><Label>(f)</Label><Text>a description of the circumstances of any release in liquid form in the environment and any mitigating measures taken; and</Text></Paragraph><Paragraph lims:inforce-start-date="2017-06-02" lims:fid="745708" lims:id="745708"><Label>(g)</Label><Text>a description of the measures taken following any release in liquid form in the environment to prevent a subsequent occurrence.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2017-06-02" lims:fid="745709" lims:id="745709"><Label>(2)</Label><Text>In the event of a release in the environment of less than 100 L of a petroleum product or an allied petroleum product, in liquid form, the report under paragraph 212(1)(a) of the <XRefExternal reference-type="act" link="C-15.31">Canadian Environmental Protection Act, 1999</XRefExternal> is not required.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745711" lims:id="745711">SOR/2012-99, s. 26; SOR/2017-110, s. 35</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745712" lims:id="745712" level="1"><TitleText>Withdrawal from Service</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745713" lims:id="745713"><Label>42</Label><Text>The owner or operator of a storage tank system may withdraw the system or any component of it from service</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745714" lims:id="745714"><Label>(a)</Label><Text>temporarily, if the withdrawal lasts less than two years; or</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745715" lims:id="745715"><Label>(b)</Label><Text>permanently.</Text></Paragraph></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745716" lims:id="745716" level="1"><TitleText>Temporary Withdrawal from Service</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745717" lims:id="745717"><Label>43</Label><Text>The owner or operator of a storage tank system that temporarily withdraws the system or any component of it from service must keep a record of the date on which they withdrew the system or component from service and must ensure that</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745718" lims:id="745718"><Label>(a)</Label><Text>if the system is equipped with a cathodic protection system, the cathodic protection system is maintained and operated during the withdrawal;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745719" lims:id="745719"><Label>(b)</Label><Text>if the system has either underground tanks, other than vertically-oriented underground tanks, or shop-fabricated aboveground tanks and the system or its component has been out of service for more than one year, those tanks are tested for leaks using a tank precision leak detection test in accordance with section <XRefInternal>21</XRefInternal> before the system or component is returned to service;</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745720" lims:id="745720"><Label>(c)</Label><Text>if the system has field-erected aboveground tanks or vertically-oriented underground tanks and the system or its component has been out of service for more than one year, an inspection of the floor of those tanks using one of the following testing methods, namely, ultrasonic, magnetic particle, videographic or vacuum, is performed before the system or component is returned to service; and</Text></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745721" lims:id="745721"><Label>(d)</Label><Text>a label is affixed to the system’s fill pipe stating that the system is temporarily out of service.</Text></Paragraph></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745722" lims:id="745722" level="1"><TitleText>Permanent Withdrawal from Service</TitleText></Heading><Section lims:inforce-start-date="2012-05-04" lims:lastAmendedDate="2012-05-04" lims:fid="745723" lims:id="745723"><Label>44</Label><Subsection lims:inforce-start-date="2012-05-04" lims:fid="745724" lims:id="745724"><Label>(1)</Label><Text>The owner or operator of a storage tank system that permanently withdraws the system or any component of it from service must have the system or component withdrawn by a person approved to do so by the province in which the system or component is located. If no person has been approved in the province where the storage tank system or component is located, the withdrawal must be supervised by a professional engineer.</Text></Subsection><Subsection lims:inforce-start-date="2012-05-04" lims:fid="745725" lims:id="745725"><Label>(2)</Label><Text>The owner or operator must keep a record that includes the date on which they withdrew the system or component from service and that establishes that the storage tank system or component was withdrawn by an approved person or that the withdrawal was supervised by a professional engineer.</Text></Subsection><Subsection lims:inforce-start-date="2012-05-04" lims:fid="745726" lims:id="745726"><Label>(3)</Label><Text>The owner or operator of the storage tank system must ensure that</Text><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745727" lims:id="745727"><Label>(a)</Label><Text>all liquids and sludge are removed and disposed of;</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745728" lims:id="745728"><Label>(b)</Label><Text>if a tank is being withdrawn from service, the tank is purged of vapours to less than 10% of the lower flammability limit and the presence of vapours is checked with a combustible gas meter; and</Text></Paragraph><Paragraph lims:inforce-start-date="2012-05-04" lims:fid="745729" lims:id="745729"><Label>(c)</Label><Text>the withdrawal is done in a way such that there will be no immediate or long-term harmful effect on the environment and it will not constitute a danger to human life or health.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2012-05-04" lims:fid="745730" lims:id="745730"><Label>(4)</Label><Text>The owner or operator of the storage tank system must affix a label to the system’s fill pipe stating that the system is permanently out of service.</Text></Subsection><Subsection lims:inforce-start-date="2012-05-04" lims:fid="745731" lims:id="745731"><Label>(5)</Label><Text>The owner or operator must notify the Minister, in writing, of the permanent withdrawal from service of a storage tank system or any component of a storage tank system within 60 days after the day on which it is permanently withdrawn from service.</Text></Subsection><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2012-05-04" lims:fid="745733" lims:id="745733">SOR/2012-99, s. 27(E)</HistoricalNoteSubItem></HistoricalNote></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745734" lims:id="745734" level="1"><TitleText>Removal of Storage Tank Systems</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745735" lims:id="745735"><Label>45</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745736" lims:id="745736"><Label>(1)</Label><Text>If a storage tank system or any component of a storage tank system is required to be removed under these Regulations, the owner of the system must have the system or the component removed by a person approved to do so by the province in which the system is located. If no person has been approved in the province where the storage tank system is located, the owner must have the removal supervised by a professional engineer.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745737" lims:id="745737"><Label>(2)</Label><Text>The owner must keep a record establishing that the storage tank system or the component was removed by an approved person or that the removal was supervised by a professional engineer.</Text></Subsection></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745738" lims:id="745738" level="1"><TitleText>Record Keeping</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745739" lims:id="745739"><Label>46</Label><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745740" lims:id="745740"><Label>(1)</Label><Text>Subject to subsection (2) and section <XRefInternal>31</XRefInternal>, the owner or operator of a storage tank system that is required to keep a record under these Regulations must keep the record at the owner’s or operator’s place of work nearest to the system for five years after the day on which that record was made.</Text></Subsection><Subsection lims:inforce-start-date="2008-06-12" lims:fid="745741" lims:id="745741"><Label>(2)</Label><Text>The owner or operator of a storage tank system must keep the following records and documents until the system is removed:</Text><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745742" lims:id="745742"><Label>(a)</Label><Text>the record referred to in section <XRefInternal>27</XRefInternal></Text><Subparagraph lims:inforce-start-date="2008-06-12" lims:fid="745743" lims:id="745743"><Label>(i)</Label><Text>in respect of an inspection performed under section <XRefInternal>22</XRefInternal>, or</Text></Subparagraph><Subparagraph lims:inforce-start-date="2008-06-12" lims:fid="745744" lims:id="745744"><Label>(ii)</Label><Text>that includes the information referred to in paragraph <XRefInternal>27</XRefInternal>(g); and</Text></Subparagraph></Paragraph><Paragraph lims:inforce-start-date="2008-06-12" lims:fid="745745" lims:id="745745"><Label>(b)</Label><Text>the record referred to in subsection <XRefInternal>33</XRefInternal>(2) and the documents referred to in section <XRefInternal>34</XRefInternal>.</Text></Paragraph></Subsection></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745746" lims:id="745746" level="1"><TitleText>Repeal</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745747" lims:id="745747" type="amending"><Label>47</Label><Text>[Repeal]</Text></Section><Heading lims:inforce-start-date="2017-06-02" lims:fid="745748" lims:id="745748" level="1"><TitleText>Coming into Force</TitleText></Heading><Section lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745749" lims:id="745749" type="transitional"><Label>48</Label><Text>These Regulations come into force on the day on which they are registered.</Text></Section></Body><Schedule lims:inforce-start-date="2017-06-02" lims:lastAmendedDate="2020-10-26" lims:fid="745750" lims:id="745750" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2017-06-02" lims:fid="745751" lims:id="745751"><Label>SCHEDULE 1</Label><OriginatingRef>(Section 1)</OriginatingRef><TitleText>Allied Petroleum Products</TitleText></ScheduleFormHeading><List lims:inforce-start-date="2017-06-02" lims:fid="745752" lims:id="745752" first-line-indent="0" subsequent-line-indent="2" language-align="no"><Item lims:inforce-start-date="2017-06-02" lims:fid="745753" lims:id="745753"><Label>1</Label><Text>Thinners mentioned in the following standards that meet the requirements of those standards:</Text><List lims:inforce-start-date="2017-06-02" lims:fid="745754" lims:id="745754" first-line-indent="2" subsequent-line-indent="4" language-align="no"><Item lims:inforce-start-date="2017-06-02" lims:fid="745755" lims:id="745755"><Label>(a)</Label><Text>CGSB 1-GP-124, <XRefExternal reference-type="standard">Thinner for Vinyl Coatings</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745756" lims:id="745756"><Label>(b)</Label><Text>CGSB 1-GP-136, <XRefExternal reference-type="standard">Antiblush Thinner for Cellulose Nitrate Lacquer</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745757" lims:id="745757"><Label>(c)</Label><Text>CAN/CGSB-1.4, <XRefExternal reference-type="standard">Petroleum Spirits Thinner</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745758" lims:id="745758"><Label>(d)</Label><Text>CAN/CGSB-1.70, <XRefExternal reference-type="standard">High Solvency Thinner</XRefExternal></Text></Item><Item lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745759" lims:id="1273264"><Label>(e)</Label><Text>CAN/CGSB-1.110, <XRefExternal reference-type="standard">General Purpose Thinner for Lacquers</XRefExternal></Text></Item></List></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745760" lims:id="745760"><Label>2</Label><Text>Linseed oils that meet the requirements of ISO 150, <XRefExternal reference-type="standard">Raw, Refined and Boiled Linseed Oil for Paints and Varnishes — Specifications and Methods of test</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745761" lims:id="745761"><Label>3</Label><Text>Solvents that meet the requirements of CAN/CGSB-1.164, <XRefExternal reference-type="standard">Solvent for Vinyl Pretreatment Coating</XRefExternal></Text></Item><Item lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745762" lims:id="1273265"><Label>4</Label><Text>Acetone that meets the requirements of CAN/CGSB-15.50, <XRefExternal reference-type="standard">Technical Grade Acetone</XRefExternal></Text></Item><Item lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="745763" lims:id="1273266"><Label>5</Label><Text>Methyl Ethyl Ketone that meets the requirements of CAN/CGSB-15.52, <XRefExternal reference-type="standard">Technical Grade Methyl Ethyl Ketone</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745764" lims:id="745764"><Label>6</Label><Text>Ink that meets the requirements of CAN/CGSB 21.1, <XRefExternal reference-type="standard">Offset Lithographic Printing Ink</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745765" lims:id="745765"><Label>7</Label><Text>Isopropanol that meets the requirements of ASTM International Standard ASTM D770, <XRefExternal reference-type="standard">Standard Specification for Isopropyl Alcohol</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745766" lims:id="745766"><Label>8</Label><Text>Methanol that meets the requirements of ASTM International Standard ASTM D1152, <XRefExternal reference-type="standard">Standard Specification For Methanol (Methyl Alcohol)</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745767" lims:id="745767"><Label>9</Label><Text>Ethylene Glycol that meets the requirements of CGSB 3-GP-855M, <XRefExternal reference-type="standard">Ethylene Glycol, Uninhibited</XRefExternal></Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745768" lims:id="745768"><Label>10</Label><Text>Benzene</Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745769" lims:id="745769"><Label>11</Label><Text>Toluene</Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745770" lims:id="745770"><Label>12</Label><Text>Biodiesel</Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745771" lims:id="745771"><Label>13</Label><Text>E85 fuel</Text></Item><Item lims:inforce-start-date="2017-06-02" lims:fid="745772" lims:id="745772"><Label>14</Label><Text>Oxygenated gasoline</Text></Item></List><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2017-06-02" lims:fid="745774" lims:id="745774">SOR/2012-99, s. 28; SOR/2017-110, s. 36</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273262" lims:id="1273262" lims:enactId="1272374">SOR/2020-235, s. 5(E)</HistoricalNoteSubItem><HistoricalNoteSubItem lims:inforce-start-date="2020-10-26" lims:enacted-date="2020-10-26" lims:fid="1273263" lims:id="1273263" lims:enactId="1272376">SOR/2020-235, s. 6</HistoricalNoteSubItem></HistoricalNote></Schedule><Schedule lims:inforce-start-date="2012-05-04" lims:lastAmendedDate="2012-05-04" lims:fid="745775" lims:id="745775" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2012-05-04" lims:fid="745776" lims:id="745776"><Label>SCHEDULE 2</Label><OriginatingRef>(Subsections 28(1) and (2))</OriginatingRef><TitleText>Information Required to Identify a Storage Tank System</TitleText></ScheduleFormHeading><List lims:inforce-start-date="2012-05-04" lims:fid="745777" lims:id="745777" subsequent-line-indent="2" first-line-indent="0" language-align="no"><Item lims:inforce-start-date="2012-05-04" lims:fid="745778" lims:id="745778"><Label>1</Label><Text>Name of owner of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745779" lims:id="745779"><Label>2</Label><Text>Mailing address of owner</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745780" lims:id="745780"><Label>3</Label><Text>Name of operator of the storage tank system, if different from owner</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745781" lims:id="745781"><Label>4</Label><Text>Mailing address of operator</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745782" lims:id="745782"><Label>5</Label><Text>The allied petroleum product or the type of petroleum product stored in each tank of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745783" lims:id="745783"><Label>6</Label><Text>Location of the storage tank system (civic address or, if no civic address exists, Global Positioning System (GPS) coordinates or latitude and longitude)</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745784" lims:id="745784"><Label>7</Label><Text>Civic address of the location where the storage tank system records are stored</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745785" lims:id="745785"><Label>8</Label><Text>Months during which the storage tank system is in service</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745786" lims:id="745786"><Label>9</Label><Text>Nominal capacity of each tank of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745787" lims:id="745787"><Label>10</Label><Text>Year of installation of each tank of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745788" lims:id="745788"><Label>11</Label><Text>Type of each tank of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745789" lims:id="745789"><Label>12</Label><Text>Each tank’s ULC or API Standard Number</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745790" lims:id="745790"><Label>13</Label><Text>Material used in the construction of each tank</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745791" lims:id="745791"><Label>14</Label><Text>Type of corrosion protection of each tank</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745792" lims:id="745792"><Label>15</Label><Text>Type of secondary containment of each tank</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745793" lims:id="745793"><Label>16</Label><Text>Type of overfill protection of each tank</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745794" lims:id="745794"><Label>17</Label><Text>Type of piping of the storage tank system</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745795" lims:id="745795"><Label>18</Label><Text>Material used in the construction of the piping</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745796" lims:id="745796"><Label>19</Label><Text>Diameter of the piping</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745797" lims:id="745797"><Label>20</Label><Text>Type of corrosion protection of the piping</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745798" lims:id="745798"><Label>21</Label><Text>Type of secondary containment of the piping</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745799" lims:id="745799"><Label>22</Label><Text>Type of spill containment devices</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745800" lims:id="745800"><Label>23</Label><Text>Description of petroleum product and allied petroleum product transfer areas</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745801" lims:id="745801"><Label>24</Label><Text>Type of leak detection</Text></Item><Item lims:inforce-start-date="2012-05-04" lims:fid="745802" lims:id="745802"><Label>25</Label><Text>Type of pump for transfer to the oil-water separator</Text></Item></List><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2012-05-04" lims:fid="745804" lims:id="745804">SOR/2012-99, s. 29</HistoricalNoteSubItem></HistoricalNote></Schedule><Schedule lims:inforce-start-date="2008-06-12" lims:lastAmendedDate="2008-06-12" lims:fid="745805" lims:id="745805" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2008-06-12" lims:fid="745806" lims:id="745806"><Label>SCHEDULE 3</Label><OriginatingRef>(Paragraph <XRefInternal>28</XRefInternal>(1)(b))</OriginatingRef><TitleText>Storage Tank System Identification Progress Report</TitleText></ScheduleFormHeading><List lims:inforce-start-date="2008-06-12" lims:fid="745807" lims:id="745807" style="arabic" subsequent-line-indent="2" first-line-indent="0" language-align="no"><Item lims:inforce-start-date="2008-06-12" lims:fid="745808" lims:id="745808"><Label>1</Label><Text>Name of owner of the storage tank system</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745809" lims:id="745809"><Label>2</Label><Text>Mailing address of owner</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745810" lims:id="745810"><Label>3</Label><Text>Total number of storage tank systems owned by the owner, if known, or an estimate of the total number of storage tank systems so owned</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745811" lims:id="745811"><Label>4</Label><Text>Name of operator of each storage tank system, if different from owner and if known</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745812" lims:id="745812"><Label>5</Label><Text>Mailing address of each operator, if the operator is known</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745813" lims:id="745813"><Label>6</Label><Text>Location of each storage tank system, if known (civic address or, if no civic address exists, Global Positioning System (GPS) coordinates or latitude and longitude)</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745814" lims:id="745814"><Label>7</Label><Text>If the owner owns more than one storage tank system, the number of storage tank systems that have been identified in accordance with paragraph <XRefInternal>28</XRefInternal>(1)(a) of these Regulations</Text></Item><Item lims:inforce-start-date="2008-06-12" lims:fid="745815" lims:id="745815"><Label>8</Label><Text>A description of the measures being taken to collect the information respecting the storage tank systems remaining to be identified and a description of problems that could be encountered in the course of identifying those systems, if any</Text></Item></List></Schedule><Schedule lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:lastAmendedDate="2025-08-28" lims:fid="1536906" lims:id="1536906"><ScheduleFormHeading lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536907" lims:id="1536907"><Label>SCHEDULE 4</Label><OriginatingRef>(Subsection 14(6.1))</OriginatingRef></ScheduleFormHeading><TableGroup lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536908" lims:id="1536908" pointsize="7" topmarginspacing="10"><table lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536909" lims:id="1536909" frame="topbot"><title lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536910" lims:id="1536910">Updated Standards of the CCME Code of Practice</title><tgroup lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536911" lims:id="1536911" cols="3"><colspec colname="1" colwidth="7.84*" /><colspec colname="COLSPEC0" colwidth="25.66*" /><colspec colname="COLSPEC2" colwidth="50.57*" /><thead lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536912" lims:id="1536912"><row rowsep="0" topdouble="yes"><entry colname="1" colsep="0" rowsep="0" valign="top" /><entry colsep="0" rowsep="0" valign="top">Column 1</entry><entry colsep="0" rowsep="0" valign="top">Column 2</entry></row><row rowsep="1" valign="bottom"><entry colname="1" colsep="0" valign="bottom">Item</entry><entry colsep="0" valign="bottom">Provision of the CCME Code of Practice</entry><entry colsep="0" valign="bottom">Standard</entry></row></thead><tbody lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536913" lims:id="1536913"><row><entry colsep="0" rowsep="0">1</entry><entry colsep="0" rowheader="no" rowsep="0">3.3.1(1)(e)(iii)</entry><entry colsep="0" rowsep="0">ANSI/API Std 2350, <XRefExternal reference-type="standard">Overfill Prevention for Storage Tanks in Petroleum Facilities</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">2</entry><entry colsep="0" rowheader="no" rowsep="0">3.4.1(1)(e)(ii)</entry><entry rowsep="0"><Provision format-ref="indent-0-0" hyphenation="no"><Label>(a)</Label><Text>CAN/ULC-S661, <XRefExternal reference-type="standard">Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2583, <XRefExternal reference-type="standard">Standard for Safety for Fuel Tank Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">3</entry><entry colsep="0" rowheader="no" rowsep="0">3.5.1(1)(b)</entry><entry rowsep="0">CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">4</entry><entry colsep="0" rowheader="no" rowsep="0">3.5.1(2)</entry><entry rowsep="0">CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">5</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(a)</entry><entry rowsep="0">API Std 650, <XRefExternal reference-type="standard">Welded Tanks for Oil Storage</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">6</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(b)</entry><entry rowsep="0">CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">7</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(c)</entry><entry rowsep="0">CAN/ULC-S602, <XRefExternal reference-type="standard">Standard for Aboveground Steel Tanks for Fuel Oil and Lubricating Oil</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">8</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(d)</entry><entry rowsep="0">CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">9</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(e)</entry><entry rowsep="0">CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">10</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(f)</entry><entry rowsep="0">CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">11</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(g)</entry><entry rowsep="0">CAN/ULC 653, <XRefExternal reference-type="standard">Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">12</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(h)</entry><entry rowsep="0">CAN/ULC 677, <XRefExternal reference-type="standard">Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">13</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(i)</entry><entry rowsep="0">CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">14</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(j)</entry><entry rowsep="0">CAN/ULC 652, <XRefExternal reference-type="standard">Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">15</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.1(1)(k)</entry><entry rowsep="0">CAN/ULC-S601, <XRefExternal reference-type="standard">Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">16</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.2</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S661, <XRefExternal reference-type="standard">Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2583, <XRefExternal reference-type="standard">Standard for Safety for Fuel Tank Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">17</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.3</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S664, <XRefExternal reference-type="standard">Standard for Containment Sumps, Sump Fittings, and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2447, <XRefExternal reference-type="standard">Standard for Safety for Containment Sumps, Fittings and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">18</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.4</entry><entry rowsep="0">CAN/ULC-S668, <XRefExternal reference-type="standard">Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">19</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.6(1)(a)</entry><entry rowsep="0">API Spec 12B, <XRefExternal reference-type="standard">Specification for Bolted Tanks for Storage of Production Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">20</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.6(1)(b)</entry><entry rowsep="0">API Spec 12D, <XRefExternal reference-type="standard">Specification for Field-welded Tanks for Storage of Production Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">21</entry><entry colsep="0" rowheader="no" rowsep="0">3.6.6(1)(c)</entry><entry rowsep="0">API Spec 12F, <XRefExternal reference-type="standard">Specification for Shop-welded Tanks for Storage of Production Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">22</entry><entry colsep="0" rowheader="no" rowsep="0">3.8.1(1)(a)</entry><entry rowsep="0">API RP 651, <XRefExternal reference-type="standard">Cathodic Protection of Aboveground Petroleum Storage Tanks</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">23</entry><entry colsep="0" rowheader="no" rowsep="0">3.8.1(1)(b)</entry><entry rowsep="0">API Std 653, <XRefExternal reference-type="standard">Tank Inspection, Repair, Alteration, and Reconstruction</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">24</entry><entry colsep="0" rowheader="no" rowsep="0">3.8.1(1)(c)</entry><entry rowsep="0">NACE SP0193, <XRefExternal reference-type="standard">Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">25</entry><entry colsep="0" rowheader="no" rowsep="0">3.8.1(1)(d)</entry><entry rowsep="0">STI R893, <XRefExternal reference-type="standard">Recommended Practice for External Corrosion Protection of Shop Fabricated Aboveground Tank Floors</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">26</entry><entry colsep="0" rowheader="no" rowsep="0">3.8.2(1)(b)</entry><entry rowsep="0">API Std 653, <XRefExternal reference-type="standard">Tank Inspection, Repair, Alteration, and Reconstruction</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">27</entry><entry colsep="0" rowheader="no" rowsep="0">3.9.1(2)(a)</entry><entry rowsep="0">CAN/ULC 653, <XRefExternal reference-type="standard">Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">28</entry><entry colsep="0" rowheader="no" rowsep="0">3.9.1(2)(b)</entry><entry rowsep="0">CAN/ULC 655, <XRefExternal reference-type="standard">Standard for Aboveground Protected Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">29</entry><entry colsep="0" rowheader="no" rowsep="0">3.9.1(2)(c)</entry><entry rowsep="0">CAN/ULC 677, <XRefExternal reference-type="standard">Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">30</entry><entry colsep="0" rowheader="no" rowsep="0">3.9.2(1)(a)(i)</entry><entry rowsep="0">CAN/ULC-S668, <XRefExternal reference-type="standard">Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">31</entry><entry colsep="0" rowheader="no" rowsep="0">3.9.2(1)(a)(ii)</entry><entry rowsep="0">CAN/ULC 653, <XRefExternal reference-type="standard">Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">32</entry><entry colsep="0" rowheader="no" rowsep="0">3.10.3(1)(a)</entry><entry rowsep="0">CAN/ULC-S656, <XRefExternal reference-type="standard">Standard for Oil-Water Separators</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">33</entry><entry colsep="0" rowheader="no" rowsep="0">4.3.2</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S661, <XRefExternal reference-type="standard">Standard for Overfill Protection Devices for Flammable and Combustible Liquid Storage Tanks</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2583, <XRefExternal reference-type="standard">Standard for Safety for Fuel Tank Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">34</entry><entry colsep="0" rowheader="no" rowsep="0">4.3.3</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S664, <XRefExternal reference-type="standard">Standard for Containment Sumps, Sump Fittings, and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2447, <XRefExternal reference-type="standard">Standard for Safety for Containment Sumps, Fittings and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">35</entry><entry colsep="0" rowheader="no" rowsep="0">4.3.4</entry><entry rowsep="0"><Provision format-ref="indent-0-0" hyphenation="no"><Label>(a)</Label><Text>CAN/ULC-S664, <XRefExternal reference-type="standard">Standard for Containment Sumps, Sump Fittings, and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2447, <XRefExternal reference-type="standard">Standard for Safety for Containment Sumps, Fittings and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">36</entry><entry colsep="0" rowheader="no" rowsep="0">4.3.5</entry><entry rowsep="0">CAN/ULC-S668, <XRefExternal reference-type="standard">Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">37</entry><entry colsep="0" rowheader="no" rowsep="0">4.5.1(1)(b)(ii)</entry><entry rowsep="0">NACE SP0285, <XRefExternal reference-type="standard">External Corrosion Control of Underground Storage Tank Systems by Cathodic Protection</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">38</entry><entry colsep="0" rowheader="no" rowsep="0">4.5.3(1)(a)</entry><entry rowsep="0">CAN/ULC-S603, <XRefExternal reference-type="standard">Standard for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">39</entry><entry colsep="0" rowheader="no" rowsep="0">5.2.1(1)(a)</entry><entry rowsep="0">ASTM A53/A53M, <XRefExternal reference-type="standard">Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">40</entry><entry colsep="0" rowheader="no" rowsep="0">5.2.1(1)(b)</entry><entry rowsep="0">CSA Z245.1, <XRefExternal reference-type="standard">Steel pipe</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">41</entry><entry colsep="0" rowheader="no" rowsep="0">5.2.1(1)(c)</entry><entry rowsep="0"><Provision format-ref="indent-0-0" hyphenation="no"><Label>(a)</Label><Text>CAN/ULC-S633, <XRefExternal reference-type="standard">Standard for Flexible Connector Piping for Fuels</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2039, <XRefExternal reference-type="standard">Standard for Safety for Flexible Connector Piping for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">42</entry><entry colsep="0" rowheader="no" rowsep="0">5.2.1(1)(g)</entry><entry rowsep="0">ANSI/CAN/UL 536, <XRefExternal reference-type="standard">Standard for Safety for Flexible Metallic Hose</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">43</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(a)</entry><entry rowsep="0">CAN/ULC-S603.1, <XRefExternal reference-type="standard">Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">44</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(b)</entry><entry rowsep="0">NACE SP0169, <XRefExternal reference-type="standard">Control of External Corrosion on Underground or Submerged Metallic Piping Systems</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">45</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(c)</entry><entry rowsep="0">NACE SP0285, <XRefExternal reference-type="standard">External Corrosion Control of Underground Storage Tank Systems by Cathodic Protection</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">46</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(d)</entry><entry rowsep="0">NACE SP0193, <XRefExternal reference-type="standard">Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">47</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(e)</entry><entry rowsep="0">NACE TM0101, <XRefExternal reference-type="standard">Measurement Techniques Related to Criteria for Cathodic Protection of Underground Storage Tank Systems</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">48</entry><entry colsep="0" rowheader="no" rowsep="0">8.6.1(1)(g)</entry><entry rowsep="0">API RP 651, <XRefExternal reference-type="standard">Cathodic Protection of Aboveground Petroleum Storage Tanks</XRefExternal></entry></row><row><entry colsep="0" rowsep="0">49</entry><entry colsep="0" rowheader="no" rowsep="0">8.7.2(a)</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S664, <XRefExternal reference-type="standard">Standard for Containment Sumps, Sump Fittings, and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2447, <XRefExternal reference-type="standard">Standard for Safety for Containment Sumps, Fittings and Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row><row><entry colsep="0" rowsep="0">50</entry><entry colsep="0" rowheader="no" rowsep="0">8.7.2(b)</entry><entry rowsep="0"><Provision format-ref="indent-0-0"><Label>(a)</Label><Text>CAN/ULC-S663, <XRefExternal reference-type="standard">Standard for Spill Containment Devices for Flammable and Combustible Liquid Aboveground Storage Tanks</XRefExternal></Text></Provision><Provision format-ref="indent-0-0"><Label>(b)</Label><Text>ANSI/CAN/UL/ULC 2583, <XRefExternal reference-type="standard">Standard for Safety for Fuel Tank Accessories for Flammable and Combustible Liquids</XRefExternal></Text></Provision></entry></row></tbody></tgroup></table></TableGroup><HistoricalNote><HistoricalNoteSubItem lims:inforce-start-date="2025-08-28" lims:enacted-date="2025-08-28" lims:fid="1536915" lims:id="1536915" lims:enactId="1536174">SOR/2025-167, s. 2</HistoricalNoteSubItem></HistoricalNote></Schedule><RecentAmendments><Amendment><AmendmentCitation>SOR/2025-167</AmendmentCitation><AmendmentDate>2025-08-28</AmendmentDate></Amendment><Amendment><AmendmentCitation>SOR/2020-235</AmendmentCitation><AmendmentDate>2020-10-26</AmendmentDate></Amendment></RecentAmendments></Regulation>