Energy Efficiency Regulations, 2016
Version of section 638 from 2016-12-09 to 2017-06-27:
The following provision is not in force.
Marginal note:Energy efficiency standards
638 (1) The energy efficiency standards set out in column 2 of the table to this section apply to commercial refrigerators described in column 1 that are manufactured during the periods set out in column 3.
Marginal note:Testing standard
(2) A commercial refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C657, Test Procedure A, that are applicable to a commercial refrigerator as defined in section 636.
Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Commercial refrigerators that are closed and not transparent Edaily ≤ 0.00441 V + 4.22 On or after April 1, 2007 and before January 1, 2008 2 Commercial refrigerators that are closed and not transparent Edaily ≤ 0.00441 V + 2.76 On or after January 1, 2008 and before January 1, 2010 3 Commercial refrigerators that are closed and not transparent Edaily ≤ 0.00353 V + 2.04 On or after January 1, 2010 4 Commercial refrigerators that are transparent Edaily ≤ 0.00607 V + 5.78 On or after April 1, 2007 and before January 1, 2008 5 Commercial refrigerators that are transparent Edaily ≤ 0.00607 V + 4.77 On or after January 1, 2008 and before January 1, 2010 6 Commercial refrigerators that are transparent and that do not have pull-down temperature reduction capability Edaily ≤ 0.00424 V + 3.34 On or after January 1, 2010 7 Commercial refrigerators that are transparent and that have pull-down temperature reduction capability Edaily ≤ 0.00445 V + 3.51 On or after January 1, 2010 8 Commercial refrigerators that are open CSA C657, Table 5 On or after January 1, 2012
- Date modified: