Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerators described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A commercial refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator as defined in section 636.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Commercial refrigerators that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ 0.00441 V + 4.22On or after April 1, 2007 and before January 1, 2008
    2Commercial refrigerators that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ 0.00441 V + 2.76On or after January 1, 2008 and before January 1, 2010
    3Commercial refrigerators that are self-contained, closed and not transparentCSA C657, Test Procedure AEdaily ≤ 0.00353 V + 2.04On or after January 1, 2010 and before March 27, 2017
    4Commercial refrigerators that are self-contained and transparentCSA C657, Test Procedure AEdaily ≤ 0.00607 V + 5.78On or after April 1, 2007 and before January 1, 2008
    5Commercial refrigerators that are self-contained and transparentCSA C657, Test Procedure AEdaily ≤ 0.00607 V + 4.77On or after January 1, 2008 and before January 1, 2010
    6Commercial refrigerators that are self-contained and transparent and that do not have pull-down temperature reduction capabilityCSA C657, Test Procedure AEdaily ≤ 0.00424 V + 3.34On or after January 1, 2010 and before March 27, 2017
    7Commercial refrigerators that are self-contained and transparent and that have pull-down temperature reduction capabilityCSA C657, Test Procedure AEdaily ≤ 0.00445 V + 3.51On or after January 1, 2010 and before March 27, 2017
    8Commercial refrigerators that are self-contained and openCSA C657, Test Procedure ACSA C657, Table 5On or after January 1, 2012 and before March 27, 2017
    9Commercial refrigerators that are remote-condensingCSA C657, Test Procedure ACSA C657, Table 5On or after January 1, 2012 and before March 27, 2017
    10Commercial refrigeratorsCSA C657, Test Procedure BCSA C657, Table 6On or after March 27, 2017
  • SOR/2018-201, s. 69
  • SOR/2022-265, s. 47