SCHEDULE 4(Subsection 14(6.1))
Updated Standards of the CCME Code of Practice
| Column 1 | Column 2 | |
|---|---|---|
| Item | Provision of the CCME Code of Practice | Standard |
| 1 | 3.3.1(1)(e)(iii) | ANSI/API Std 2350, Overfill Prevention for Storage Tanks in Petroleum Facilities |
| 2 | 3.4.1(1)(e)(ii) |
|
| 3 | 3.5.1(1)(b) | CAN/ULC 652, Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil |
| 4 | 3.5.1(2) | CAN/ULC 652, Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil |
| 5 | 3.6.1(1)(a) | API Std 650, Welded Tanks for Oil Storage |
| 6 | 3.6.1(1)(b) | CAN/ULC-S601, Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids |
| 7 | 3.6.1(1)(c) | CAN/ULC-S602, Standard for Aboveground Steel Tanks for Fuel Oil and Lubricating Oil |
| 8 | 3.6.1(1)(d) | CAN/ULC-S601, Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids |
| 9 | 3.6.1(1)(e) | CAN/ULC-S601, Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids |
| 10 | 3.6.1(1)(f) | CAN/ULC 652, Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil |
| 11 | 3.6.1(1)(g) | CAN/ULC 653, Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids |
| 12 | 3.6.1(1)(h) | CAN/ULC 677, Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids |
| 13 | 3.6.1(1)(i) | CAN/ULC-S601, Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids |
| 14 | 3.6.1(1)(j) | CAN/ULC 652, Standard for Tank Assemblies for the Collection, Storage and Removal of Used Oil |
| 15 | 3.6.1(1)(k) | CAN/ULC-S601, Standard for Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids |
| 16 | 3.6.2 |
|
| 17 | 3.6.3 |
|
| 18 | 3.6.4 | CAN/ULC-S668, Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks |
| 19 | 3.6.6(1)(a) | API Spec 12B, Specification for Bolted Tanks for Storage of Production Liquids |
| 20 | 3.6.6(1)(b) | API Spec 12D, Specification for Field-welded Tanks for Storage of Production Liquids |
| 21 | 3.6.6(1)(c) | API Spec 12F, Specification for Shop-welded Tanks for Storage of Production Liquids |
| 22 | 3.8.1(1)(a) | API RP 651, Cathodic Protection of Aboveground Petroleum Storage Tanks |
| 23 | 3.8.1(1)(b) | API Std 653, Tank Inspection, Repair, Alteration, and Reconstruction |
| 24 | 3.8.1(1)(c) | NACE SP0193, Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms |
| 25 | 3.8.1(1)(d) | STI R893, Recommended Practice for External Corrosion Protection of Shop Fabricated Aboveground Tank Floors |
| 26 | 3.8.2(1)(b) | API Std 653, Tank Inspection, Repair, Alteration, and Reconstruction |
| 27 | 3.9.1(2)(a) | CAN/ULC 653, Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids |
| 28 | 3.9.1(2)(b) | CAN/ULC 655, Standard for Aboveground Protected Tank Assemblies for Flammable and Combustible Liquids |
| 29 | 3.9.1(2)(c) | CAN/ULC 677, Standard for Fire Tested Aboveground Tank Assemblies for Flammable and Combustible Liquids |
| 30 | 3.9.2(1)(a)(i) | CAN/ULC-S668, Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks |
| 31 | 3.9.2(1)(a)(ii) | CAN/ULC 653, Standard for Aboveground Horizontal Steel Contained Tank Assemblies for Flammable and Combustible Liquids |
| 32 | 3.10.3(1)(a) | CAN/ULC-S656, Standard for Oil-Water Separators |
| 33 | 4.3.2 |
|
| 34 | 4.3.3 |
|
| 35 | 4.3.4 |
|
| 36 | 4.3.5 | CAN/ULC-S668, Standard for Liners Used for Secondary Containment of Aboveground Flammable and Combustible Liquid Tanks |
| 37 | 4.5.1(1)(b)(ii) | NACE SP0285, External Corrosion Control of Underground Storage Tank Systems by Cathodic Protection |
| 38 | 4.5.3(1)(a) | CAN/ULC-S603, Standard for Steel Underground Tanks for Flammable and Combustible Liquids |
| 39 | 5.2.1(1)(a) | ASTM A53/A53M, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless |
| 40 | 5.2.1(1)(b) | CSA Z245.1, Steel pipe |
| 41 | 5.2.1(1)(c) |
|
| 42 | 5.2.1(1)(g) | ANSI/CAN/UL 536, Standard for Safety for Flexible Metallic Hose |
| 43 | 8.6.1(1)(a) | CAN/ULC-S603.1, Standard for External Corrosion Protection Systems for Steel Underground Tanks for Flammable and Combustible Liquids |
| 44 | 8.6.1(1)(b) | NACE SP0169, Control of External Corrosion on Underground or Submerged Metallic Piping Systems |
| 45 | 8.6.1(1)(c) | NACE SP0285, External Corrosion Control of Underground Storage Tank Systems by Cathodic Protection |
| 46 | 8.6.1(1)(d) | NACE SP0193, Application of Cathodic Protection to Control External Corrosion of Carbon Steel On-Grade Storage Tank Bottoms |
| 47 | 8.6.1(1)(e) | NACE TM0101, Measurement Techniques Related to Criteria for Cathodic Protection of Underground Storage Tank Systems |
| 48 | 8.6.1(1)(g) | API RP 651, Cathodic Protection of Aboveground Petroleum Storage Tanks |
| 49 | 8.7.2(a) |
|
| 50 | 8.7.2(b) |
|